background image

Gru

ndfo

s compa

ni

es

Australia

GRUNDFOS Pumps Pty. Ltd. 
P.O. Box 2040 
Regency Park 
South Australia 5942 
Phone: +61-8-8461-4611 
Telefax: +61-8-8340 0155

Indonesia

PT GRUNDFOS Pompa 
Jl. Rawa Sumur III, Blok III / CC-1 
Kawasan Industri, Pulogadung 
Jakarta 13930 
Phone: +62-21-460 6909 
Telefax: +62-21-460 6910 / 460 6901 

Malaysia

GRUNDFOS Pumps Sdn. Bhd.
7 Jalan Peguam U1/25
Glenmarie Industrial Park
40150 Shah Alam
Selangor 
Phone: +60-3-5569 2922
Telefax: +60-3-5569 2866

New Zealand

GRUNDFOS Pumps NZ Ltd.
17 Beatrice Tinsley Crescent
North Harbour Industrial Estate
Albany, Auckland
Phone: +64-9-415 3240
Telefax: +64-9-415 3250

Taiwan

GRUNDFOS Pumps (Taiwan) Ltd. 
7 Floor, 219 Min-Chuan Road 
Taichung, Taiwan, R.O.C. 
Phone: +886-4-2305 0868
Telefax: +886-4-2305 0878

Philippines

GRUNDFOS Pumps (Philippines), Inc. 
2308 Ground Floor Natividad Building, 
Pasong Tamo Extension 
1231 Makati City 
Phone: +632-840-2300/ 813-1547 

Содержание PM Rain

Страница 1: ...GRUNDFOS INSTRUCTIONS PM Rain Installation and operating instructions...

Страница 2: ...proximation of the laws of the EC member states Low Voltage Directive 2006 95 EC Standards used EN 60730 1 2000 and EN 60730 2 6 2008 EMC Directive 2004 108 EC Standards used EN 60730 1 2000 and EN 60...

Страница 3: ...Functions 10 8 1 Anti cycling 10 8 2 Dry running protection 10 9 Frost protection 11 10 List of warnings 12 11 Technical data 12 12 Fault finding 13 13 Further product information 14 14 Disposal 14 W...

Страница 4: ...hout solid particles or fibres that may attack the unit mechanically or chemically 3 2 Temperatures 3 2 1 Liquid temperature 0 to 60 C 3 2 2 Ambient temperature 0 to 55 C 3 3 Operating pressure Max 10...

Страница 5: ...e unit so that the height between the unit and the highest tapping point does not exceed the values in the table below Default setting See section 5 1 DIP switches Note Use a suitable thread seal tape...

Страница 6: ...rther adjustment is necessary repeat from point 2 When the pressure reducing valve has been adjusted correctly adjust the start pressure accordingly See section 5 1 DIP switches 10 Refit the PM Rain c...

Страница 7: ...l installation make sure that the power supply cannot be accidentally switched on The unit must be connected to an external mains switch with a minimum contact gap of 3 mm in all poles As a precaution...

Страница 8: ...witch 2 ON Start pressure 2 5 0 5 1 4 bar Start pressure 250 50 100 400 kPa See section 7 2 1 Starting and stopping conditions All set to OFF pstart 2 5 bar pstart 250 kPa 5 STOP START 1 BAR Start sto...

Страница 9: ...at a pressure above 2 5 bar 250 kPa the mains water back up will remain inactive See fig 7 If rainwater is no longer available the PM Rain will stop the pump when dry running occurs When the system p...

Страница 10: ...atically reset To enable the function set DIP switch 6 to ON See section 5 1 DIP switches 8 1 Anti cycling To detect inadvertent starts and stops of the pump in case of a failure in the installation t...

Страница 11: ...not been primed within 3 minutes of operation the dry running warning will reappear The auto reset function will attempt to restart the pump after 24 hours This will be repeated for five days and if r...

Страница 12: ...art stop sequences within a short period Each pump start is delayed a few seconds to protect the installation The start delay is active until normal operation has been re established Note The protecti...

Страница 13: ...ump is blocked c The pump is defective Repair or replace the pump d The PM Rain is defective Repair or replace the PM Rain 3 The pump does not start when water is consumed Pump on is off a Too big dif...

Страница 14: ...ction 8 1 Anti cycling b Cycling There is a minor leakage in the system Note For system without pressure tank Check the system for leaks See section 8 1 Anti cycling c Cycling The pressure tank has no...

Страница 15: ...ndix 1 Fig 8 Wiring diagrams Fig 9 Dimensions TM04 9528 4510 TM04 1953 1508 IN M 3 L1 L3 N L1 L2 PE N U V 1x230 V 50 60 Hz PE 6 OUT 5 4 3 2 1 IN M 1 L1 L1 N PE N U V 1x230 V 50 60 Hz PE 6 OUT 5 4 3 2...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...Peguam U1 25 Glenmarie Industrial Park 40150 Shah Alam Selangor Phone 60 3 5569 2922 Telefax 60 3 5569 2866 New Zealand GRUNDFOS Pumps NZ Ltd 17 Beatrice Tinsley Crescent North Harbour Industrial Est...

Страница 20: ...ahead makes it possible Innovation is the essence The name Grundfos the Grundfos logo and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A S or Grundfos A S Denma...

Отзывы: