6.

The red "Warning" 
indicator light is 
permanently on.

a)

Dry running. The pump needs water.

Check the pipework.

b)

The power supply to the pump is 
disconnected after the PM Rain.

Check the plug and cable connections.

 

If the pump has a built-in circuit 
breaker, check that it is switched off.

c)

The motor protection of the pump has 
tripped due to overload.

Check if the motor/pump is blocked.

d)

The pump is defective.

Repair or replace the pump.

e)

The PM Rain is defective.

Repair or replace the PM Rain.

7.

The red "Warning" 
indicator light 
flashes once per 
period.

a)

Cycling.
A tap has not been closed entirely 
after use. 
Note: For system without pressure 
tank.

Check that all taps have been closed.
See section 8.1 Anti-cycling.

b)

Cycling.
There is a minor leakage in the system. 
Note: For system without pressure 
tank.

Check the system for leaks.
See section 8.1 Anti-cycling.

c)

Cycling.
The pressure tank has no precharge 
pressure, or the tank size is 
insufficient. 
Note: For system with pressure tanks.

Check the tank precharge pressure, and 
recharge the tank, if necessary.
If the size of the pressure tank is 
insufficient, set DIP switch 5 to "OFF", or 
replace the pressure tank.
See section 8.1 Anti-cycling.

8.

The red "Warning" 
indicator light 
flashes three times 
per period, and each 
pump start is 
delayed a few 
seconds.

a)

Too many start/stop sequences within 
a short period.
The pressure tank has no precharge 
pressure, or the tank size is 
insufficient.

Check the tank precharge pressure, and 
recharge the tank, if necessary.
If the size of the pressure tank is 
insufficient, set DIP switch 5 to "OFF", or 
replace the pressure tank.

b)

Too many start/stop sequences within 
a short period.
The PM Rain is set to start/stop with 
1 bar (100 kPa) differential pressure, 
i.e. DIP switch 5 is set to "ON", but no 
pressure tank has been installed in the 
system.

Set DIP switch 5 to "OFF".

9.

The red "Warning" 
indicator light flashes 
four times per period. 

a)

Pressure sensor fault.

Repair or replace the PM Rain.

Fault

Cause

Remedy

Содержание PM Rain

Страница 1: ...GRUNDFOS INSTRUCTIONS PM Rain Installation and operating instructions...

Страница 2: ...proximation of the laws of the EC member states Low Voltage Directive 2006 95 EC Standards used EN 60730 1 2000 and EN 60730 2 6 2008 EMC Directive 2004 108 EC Standards used EN 60730 1 2000 and EN 60...

Страница 3: ...Functions 10 8 1 Anti cycling 10 8 2 Dry running protection 10 9 Frost protection 11 10 List of warnings 12 11 Technical data 12 12 Fault finding 13 13 Further product information 14 14 Disposal 14 W...

Страница 4: ...hout solid particles or fibres that may attack the unit mechanically or chemically 3 2 Temperatures 3 2 1 Liquid temperature 0 to 60 C 3 2 2 Ambient temperature 0 to 55 C 3 3 Operating pressure Max 10...

Страница 5: ...e unit so that the height between the unit and the highest tapping point does not exceed the values in the table below Default setting See section 5 1 DIP switches Note Use a suitable thread seal tape...

Страница 6: ...rther adjustment is necessary repeat from point 2 When the pressure reducing valve has been adjusted correctly adjust the start pressure accordingly See section 5 1 DIP switches 10 Refit the PM Rain c...

Страница 7: ...l installation make sure that the power supply cannot be accidentally switched on The unit must be connected to an external mains switch with a minimum contact gap of 3 mm in all poles As a precaution...

Страница 8: ...witch 2 ON Start pressure 2 5 0 5 1 4 bar Start pressure 250 50 100 400 kPa See section 7 2 1 Starting and stopping conditions All set to OFF pstart 2 5 bar pstart 250 kPa 5 STOP START 1 BAR Start sto...

Страница 9: ...at a pressure above 2 5 bar 250 kPa the mains water back up will remain inactive See fig 7 If rainwater is no longer available the PM Rain will stop the pump when dry running occurs When the system p...

Страница 10: ...atically reset To enable the function set DIP switch 6 to ON See section 5 1 DIP switches 8 1 Anti cycling To detect inadvertent starts and stops of the pump in case of a failure in the installation t...

Страница 11: ...not been primed within 3 minutes of operation the dry running warning will reappear The auto reset function will attempt to restart the pump after 24 hours This will be repeated for five days and if r...

Страница 12: ...art stop sequences within a short period Each pump start is delayed a few seconds to protect the installation The start delay is active until normal operation has been re established Note The protecti...

Страница 13: ...ump is blocked c The pump is defective Repair or replace the pump d The PM Rain is defective Repair or replace the PM Rain 3 The pump does not start when water is consumed Pump on is off a Too big dif...

Страница 14: ...ction 8 1 Anti cycling b Cycling There is a minor leakage in the system Note For system without pressure tank Check the system for leaks See section 8 1 Anti cycling c Cycling The pressure tank has no...

Страница 15: ...ndix 1 Fig 8 Wiring diagrams Fig 9 Dimensions TM04 9528 4510 TM04 1953 1508 IN M 3 L1 L3 N L1 L2 PE N U V 1x230 V 50 60 Hz PE 6 OUT 5 4 3 2 1 IN M 1 L1 L1 N PE N U V 1x230 V 50 60 Hz PE 6 OUT 5 4 3 2...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...Peguam U1 25 Glenmarie Industrial Park 40150 Shah Alam Selangor Phone 60 3 5569 2922 Telefax 60 3 5569 2866 New Zealand GRUNDFOS Pumps NZ Ltd 17 Beatrice Tinsley Crescent North Harbour Industrial Est...

Страница 20: ...ahead makes it possible Innovation is the essence The name Grundfos the Grundfos logo and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A S or Grundfos A S Denma...

Отзывы: