12. Fault finding

Warning

Before starting work on the pump/PM Rain, make sure that the power supply has been 
switched off and that it cannot be accidentally switched on.

Fault

Cause

Remedy

1.

The pump runs 
continuously.

a)

Air lock in the system.

Release air from the system. 
Open valves (taps, flush toilets, operate 
washing machine) from nearest to 
furthest outlet. Repeat, if necessary.

b)

The pump cable plug is inserted 
directly into the power supply socket.

Insert the pump cable plug into the 
PM Rain and the PM Rain plug into the 
power supply socket.

c)

Water is still being used. 

Check all taps, toilets, and appliances 
connected to the PM Rain to ensure that 
they are turned off. If the pump does not 
stop, switch off the pump, and check the 
discharge pipe for leaks.

d)

Water is leaking on the discharge side. Check for leaks.

e)

The start pressure is set too high.

Decrease the start pressure.
See section 5.1 DIP switches.

f)

The non-return valve is stuck in open 
position.

Clean or replace the valve.

g)

The PM Rain is defective.

Repair or replace the PM Rain.

2.

The green "Pump 
on" indicator light is 
on, but the pump 
does not start.

a)

The power supply to the pump is 
disconnected after the PM Rain.

Check the plug and cable connections.

b)

The motor protection of the pump has 
tripped due to overload.

Check if the pump is blocked.

c)

The pump is defective.

Repair or replace the pump.

d)

The PM Rain is defective.

Repair or replace the PM Rain.

3.

The pump does not 
start when water is 
consumed. "Pump 
on" is off.

a)

Too big difference in height between 
the PM Rain and the tapping point.

Adjust the installation, or increase the 
start pressure.
See section 5.1 DIP switches.

b)

The PM Rain is defective.

Repair or replace the PM Rain.

c)

The pump cable plug is not inserted 
into the PM Rain.

Check the plug and cable connections.

d)

No power supply. No light in Rain 
water or Mains water indicator lights.

Contact an electrician, or restore the 
power supply.

4.

Frequent starts and 
stops.

a)

DIP switch 5 set to "ON".
Note: For system without pressure 
tank.

Set DIP switch 5 to "OFF".
See section 5.1 DIP switches.

b)

Leakage in the pipework.

Check and repair the pipework.

c)

The non-return valve is stuck in open 
position.

Clean or replace the non-return valve.

d)

The pressure tank has no precharge 
pressure, or the tank size is 
insufficient. 
Note: For system with pressure tank.

Check the tank precharge pressure, and 
recharge the tank, if necessary.
If the size of the pressure tank is 
insufficient, set DIP switch 5 to "OFF", or 
replace the pressure tank.

5.

The pump does not 
stop.

a)

The pump cannot deliver the 
necessary discharge pressure.

Replace the pump.

b)

The start pressure is set too high.

Decrease the start pressure.

c)

The PM Rain is defective.

Repair or replace the PM Rain.

d)

The non-return valve is stuck in open 
position.

Clean or replace the non-return valve.

Содержание PM Rain

Страница 1: ...GRUNDFOS INSTRUCTIONS PM Rain Installation and operating instructions...

Страница 2: ...proximation of the laws of the EC member states Low Voltage Directive 2006 95 EC Standards used EN 60730 1 2000 and EN 60730 2 6 2008 EMC Directive 2004 108 EC Standards used EN 60730 1 2000 and EN 60...

Страница 3: ...Functions 10 8 1 Anti cycling 10 8 2 Dry running protection 10 9 Frost protection 11 10 List of warnings 12 11 Technical data 12 12 Fault finding 13 13 Further product information 14 14 Disposal 14 W...

Страница 4: ...hout solid particles or fibres that may attack the unit mechanically or chemically 3 2 Temperatures 3 2 1 Liquid temperature 0 to 60 C 3 2 2 Ambient temperature 0 to 55 C 3 3 Operating pressure Max 10...

Страница 5: ...e unit so that the height between the unit and the highest tapping point does not exceed the values in the table below Default setting See section 5 1 DIP switches Note Use a suitable thread seal tape...

Страница 6: ...rther adjustment is necessary repeat from point 2 When the pressure reducing valve has been adjusted correctly adjust the start pressure accordingly See section 5 1 DIP switches 10 Refit the PM Rain c...

Страница 7: ...l installation make sure that the power supply cannot be accidentally switched on The unit must be connected to an external mains switch with a minimum contact gap of 3 mm in all poles As a precaution...

Страница 8: ...witch 2 ON Start pressure 2 5 0 5 1 4 bar Start pressure 250 50 100 400 kPa See section 7 2 1 Starting and stopping conditions All set to OFF pstart 2 5 bar pstart 250 kPa 5 STOP START 1 BAR Start sto...

Страница 9: ...at a pressure above 2 5 bar 250 kPa the mains water back up will remain inactive See fig 7 If rainwater is no longer available the PM Rain will stop the pump when dry running occurs When the system p...

Страница 10: ...atically reset To enable the function set DIP switch 6 to ON See section 5 1 DIP switches 8 1 Anti cycling To detect inadvertent starts and stops of the pump in case of a failure in the installation t...

Страница 11: ...not been primed within 3 minutes of operation the dry running warning will reappear The auto reset function will attempt to restart the pump after 24 hours This will be repeated for five days and if r...

Страница 12: ...art stop sequences within a short period Each pump start is delayed a few seconds to protect the installation The start delay is active until normal operation has been re established Note The protecti...

Страница 13: ...ump is blocked c The pump is defective Repair or replace the pump d The PM Rain is defective Repair or replace the PM Rain 3 The pump does not start when water is consumed Pump on is off a Too big dif...

Страница 14: ...ction 8 1 Anti cycling b Cycling There is a minor leakage in the system Note For system without pressure tank Check the system for leaks See section 8 1 Anti cycling c Cycling The pressure tank has no...

Страница 15: ...ndix 1 Fig 8 Wiring diagrams Fig 9 Dimensions TM04 9528 4510 TM04 1953 1508 IN M 3 L1 L3 N L1 L2 PE N U V 1x230 V 50 60 Hz PE 6 OUT 5 4 3 2 1 IN M 1 L1 L1 N PE N U V 1x230 V 50 60 Hz PE 6 OUT 5 4 3 2...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...Peguam U1 25 Glenmarie Industrial Park 40150 Shah Alam Selangor Phone 60 3 5569 2922 Telefax 60 3 5569 2866 New Zealand GRUNDFOS Pumps NZ Ltd 17 Beatrice Tinsley Crescent North Harbour Industrial Est...

Страница 20: ...ahead makes it possible Innovation is the essence The name Grundfos the Grundfos logo and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A S or Grundfos A S Denma...

Отзывы: