7.3.3 Contact input
In the "System choice" menu, switch to the "Contact input" menu
using the [F3] key.
The max. flow in the main water line are entered in this menu.
• Use the [F1] key to switch to the variable field "0000.0 m³/h",
and enter the max. flow rate. Enter using the [UP], [DOWN],
[LEFT], [RIGHT] arrow keys analogous to the "Current input"
entry.
• Confirm using [Enter] key.
• Use the [Enter] or [RIGHT] arrow key to switch to the menu:
The quantity (ppm) of ClO
2
added and the pulses/litre of the
contact water meter are entered in this menu.
• Switch to the variable field "0.00" using the [F1] key.
• Use the [UP] and [DOWN] keys to change the numerical
value, and the arrow [LEFT] and [RIGHT] keys to change the
input field.
• Enter the value to be added.
• Use the [F1] key to switch to the variable field "water meter
00.000", and enter the contacts of the existing contact water
meter.
• Confirm using [Enter] key.
• Use the [Enter] or [RIGHT] arrow key to switch to the menu:
The requisite system capacity, as well as the pulses output by the
water meter are now calculated in this menu.
Example:
• Use the [Enter] key to switch to the menu:
The max. and min. volume of water, which can be supplied with
ClO
2
through the set quantity to be added (ppm), and the system
size, are specified in this menu. The system switches off below
the min. water quantity (system capacity < 2.5 %).
1. Confirm using [Enter] key.
2. Use the [Enter] key to return to the "Operation mode" menu.
3. Press the [Escape] key twice to return to the main menu.
Basic load setting
Use the [F1] key to switch to the variable field 0 g/h, and set a
basic load.
7.3.4 Manual control
• Scroll with the arrow [RIGHT] key in the "Operation mode"
menu.
Display page 2
• Select the "Manual control" mode using the [F1] key.
• Use the [Enter] and [Escape] key to return to the "Operation
mode" menu.
7.3.5 Target value external
• Scroll with the arrow [RIGHT] key in the "Operation mode"
menu.
Display (page 2)
• Select the "Bus control" mode using the [F2] key.
• Use the [Enter] and [Escape] key to return to the "Operation
mode" menu.
Contact input
Max. flow of H
2
O
0000.0 m³/h
>
Contact input
<
added
0.00 ppm
Water meter
00.000
pulses/litre
>
Note
The control for the system can process a max. rate of
50 pulses/sec. If a value greater than 50 pulses/sec.
is calculated, use a different contact water meter.
Contact input
<
0 g/h = 0.00 pulses/sec.
9 g/h = 8.33 pulses/sec.
Default quantity of ClO
2
:
0.3 ppm
Main water quantity:
30 m³/h
Contact water meter:
1 pulse/litre
Max. system capacity:
0.3 ppm x 30 m³/h = 9 g/h
Water meter:
1 pulse/litre x 30 m³/h x
1000/3600 = 8.33 pulses/sec.
Note
Select or set the contact water meter in such a way
that, at max. system capacity, at least 5 pulses/sec.
are transmitted to the controller.
Contact input
<
Flow of H
2
O
Max.
xxx.x m³/h
Min.
xxx.x m³/h
Contact input
activated
Note
The preset water flow rate in the "contact or current
input" mode is [m³/h].
Use the [F1] key to select other displayed units: [l/s]
and [%].
Contact input
<
0 g/h = 0.00 pulses/sec.
9 g/h = 8.33 pulses/sec.
Note
The basic load depends on the system type. It is
bigger than 2.5 % of the system capacity.
For example, for the system type OCD-164-1000 the
basic load is bigger than 0.25 g/h.
Operation mode
<
1 Manual control
2 Target value ext.
Manual control
activated
Note
When "Manual control" is selected, the installation
can only be started in manual mode.
Operation mode
<
1 Manual control
2 Target value ext.
Note
The "Target value ext." menu option is only visible, if
a bus system has been selected in the "Basic
settings/bus options" menu.
Target value external
activated
Содержание Oxiperm OCD-164
Страница 2: ...2...
Страница 247: ...Fran ais FR 247 4 crou filtre PVC gris...
Страница 420: ...RU 420 1 10 1 10 1 20 TrinkwV 2001 0 4 1 10 2 1 10 3 EN 12671 D 15 7 5 DIN EN 938 9 0 DIN EN 939 HCl NaClO2...
Страница 422: ...RU 422 10 10...
Страница 430: ...RU 430 5 4 2 0 1 1 8 5 4 3 42 9 5 4 4 ClO2 ClO2 ClO2 2 3 3 TM04 8200 4510 11 1D O2 O TM04 8201 4510 1D O2 O...
Страница 431: ...RU 431 10 5 5 2 1 5 5 6 5 6 1 5 6 1 TM04 8202 4510 50 60 6 20 11 1D O2 O...
Страница 432: ...RU 432 5 6 2 1 2 3 20 20 4 11 4 5 4 4 5 4 6 5 6 5 6 TM04 8203 4510 1 20 2 3 4 5 6...
Страница 455: ...RU 455 34 HCl 35 HCl 36 NaClO2 37 NaClO2 38 H2O 39 H2O 40 ClO2 41 HCl 42 NaClO2 43 H2O 44 45 46 47...
Страница 526: ...526...