2.3 Inlet conditions

The bottom of the pump strainer must be at least 25 
mm above the bottom of the tank. See fig. 

6

 or 

7

.

MTH pumps must be installed vertically, and the 
drain hole in the motor stool must have access to the 
tank.
The pumps are designed to provide full performance 
down to a level of A mm above the bottom of the 
strainer. 
At a liquid level between A and B mm above the 
bottom of the strainer, the built-in priming screw will 
protect the pump against dry running.

Fig. 6

MTH 2, 4 and 8

Fig. 7

MTH 10 and 15

2.4 Electrical connection

Operating voltage and operating frequency are 
stated on the motor nameplate. Check that the motor 
is suitable for the power supply available at the 
installation site.
The voltage quality for MG motors, measured at the 
motor terminals, must be ± 10 % of the rated voltage 
during continuous operation (including variation in 
the supply voltage and losses in cables).
The electrical installation must be carried out by 
authorised persons in accordance with local 
regulations.
The wiring diagram is located in the terminal box 
cover.
The terminal box of single-speed motors normally 
contains six winding terminals and at least one earth 
terminal.

Single-phase motor

Connect single-phase motors to the mains in 
accordance with the instructions located in the 
terminal box cover.

Three-phase motor

Three-phase motors can be connected in star (Y) or 
delta (D) according to IEC 60034-8. See the wiring 
diagram in the terminal box cover.
Voltage and connection are stated on the nameplate.

Example: 220-240 V D / 380-415 V Y

If the voltage supply is 220-240 V, the motor must 
be connected in delta.

If the voltage supply is 380-415 V, the motor must 
be connected in star.

Pump type

A [mm]

B [mm]

MTH 2, 4 and 8

37

25

MTH 10 and 15

40

28

TM

07 

02

91 

471

7

TM0

7

 0

29

0 4

7

1

7

A

B

25mm

25mm

B

A

WARNING

Electric shock

Death or serious personal injury
- Before starting any work on the product, 

make sure that the power supply has 
been switched off and that it cannot be 
accidentally switched on. Connect the 
pump to an external main switch close 
to the pump and to a motor-protective 
circuit breaker or a CUE frequency 
converter.

- Make sure you can lock the main switch 

in OFF position (isolated). Type and 
requirements as specified in EN 60204-
1, 5.3.2.

Содержание MTH 10

Страница 1: ...MTH Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...k mounting 3 2 3 Inlet conditions 5 2 4 Electrical connection 5 3 Starting up the product 7 3 1 Operating the product 7 4 Product introduction 7 4 1 Applications 7 4 2 Identification 7 5 Servicing the...

Страница 3: ...ts A filtration system must be installed in the tank system to avoid that impurities in the liquid block the pump Fig 2 Example of a filtration system Observe these instructions for explosion proof pr...

Страница 4: ...install a bypass line TM07 0453 5117 TM07 0454 5117 Measurement Dimension B Depending on pump type C Depending on motor type X1 200 mm X2 150 mm Y1 This measurement must be at least 30 mm longer than...

Страница 5: ...ng diagram is located in the terminal box cover The terminal box of single speed motors normally contains six winding terminals and at least one earth terminal Single phase motor Connect single phase...

Страница 6: ...tor to the motor stool 2 Turn the motor to the required position 3 Replace and tighten the four bolts The electric motor must be connected to the supply as shown in the diagram inside the terminal box...

Страница 7: ...s pumps type MTH are multistage centrifugal pumps designed for pumping liquids for machine tools condensate transfer liquid transfer in industrial washing machines and similar applications The pumps a...

Страница 8: ...E EPDM V FKM WARNING Electric shock Death or serious personal injury Before starting any work on the product make sure that the power supply has been switched off and that it cannot be accidentally s...

Страница 9: ...cooled by the pumped liquid Pump bearings The pump bearings are also lubricated by the pumped liquid Motor bearings The motor ball bearings are grease packed and sealed for life No further lubrication...

Страница 10: ...acts in the motor protective circuit breaker are not making contact or the coil is faulty Replace contacts or magnetic coil e The control circuit is defective Repair the control circuit f The motor is...

Страница 11: ...point designated by the local waste disposal authorities The separate collection and recycling of such products will help protect the environment and human health See also end of life information at...

Страница 12: ...abilit que le produit MTH auquel se r f re cette d claration est conforme aux Directives du Conseil concernant le rapprochement des l gislations des tats membres CE UE relatives aux normes nonc es ci...

Страница 13: ...marked with the minimum efficiency index MEI See pump nameplate This EC EU declaration of conformity is only valid when published as part of the Grundfos installation and operating instructions publi...

Страница 14: ...14 2 RUS MTH MTH KAZ MTH MTH KG MTH 2 MTH ARM MTH 1 2 3...

Страница 15: ...15 MTH 99310686 10000142884 D...

Страница 16: ...1 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 013...

Страница 17: ...hona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa Grundf...

Страница 18: ...404 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 G...

Отзывы: