10. Fault finding

Warning

Before starting fault finding, switch off 
the power supply. Make sure that the 
power supply cannot be accidentally 
switched on.

Fault

Cause

Remedy

1.

The pump does 
not start.

a)

Supply failure.

Cut in the circuit breaker or replace the fuses. 
If the new fuses also blow, check the electric 
installation.

b)

Pump blocked by impurities.

Clean the pump. Check or replace the strainer 
in the suction pipe.

c)

Motor defective.

Repair or replace the motor. *

d)

Three-phase motors:
The motor-protective circuit 
breaker has tripped.

Cut in the motor-protective circuit breaker.
If the problem still persists, check these two 
possible causes:
• Impeller stuck.

Clean the pump according to section 

8.1

.

• Motor defective.

Repair or replace the motor. *

2.

The pump runs, 
but gives no water 
or delivers a 
reduced quantity 
of water.

a)

Pump is not filled with water.

Prime the pump. See section 

7.

b)

Suction pipe blocked by 
impurities.

Clean the pump. Check or replace the strainer 
in the suction pipe.

c)

Pump blocked by impurities.

Clean the pump. Check or replace the strainer 
in the suction pipe.

d)

Suction lift is too high (over 7 
metres).

Change the position of the pump.

e)

Suction pipe is too long.

Change the position of the pump.

f)

Diameter of suction pipe is 
too small.

Replace the suction pipe.

g)

Suction pipe is not immersed 
deeply enough.

Make sure that the suction pipe is immersed 
sufficiently.

h)

Suction pipe is leaking.

Repair or replace the pipe.

i)

Ejector valve setting is 
incorrect (only pumps fitted 
with ejector valve).

Set the valve. See section 

5.2

.

j)

Direction of rotation is 
incorrect (three-phase 
pumps).

Interchange two phases.

3. The pump runs, but 

gives no water or 
delivers a reduced 
quantity of water at 
high pressure.

a)

Discharge pipe blocked.

Clean pipe or open isolating valves, if fitted.
Check that no additional work is being carried 
out in the system.

Содержание JP5

Страница 1: ...JP Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...torens typeskilt Anvendt standard EN 60034 30 2009 DE EG Konformit tserkl rung Wir Grundfos erkl ren in alleiniger Verantwortung dass die Produkte JP 5 und JP 6 auf die sich diese Erkl rung bezieht mi...

Страница 3: ...Piem rotie standarti EN 809 1998 un EN 60204 1 2006 Zema sprieguma direkt va 2006 95 EK Piem rotie standarti EN 60335 1 2002 un EN 60335 2 41 2003 Elektromagn tisk s sader bas direkt va 2004 108 EK E...

Страница 4: ...ktor sa toto prehl senie vzt ahuje s v s lade s ustanoven m smernice Rady pre zbl enie pr vnych predpisov lensk ch t tov Eur pskeho spolo enstva v oblastiach Smernica pre strojov zariadenie 2006 42 EC...

Страница 5: ...ldirgesi Grundfos olarak bu beyannameye konu olan JP 5 ve JP 6 r nlerinin AB yesi lkelerin kanunlar n birbirine yakla t rma zerine Konsey Direktifleriyle uyumlu oldu unun yaln zca bizim sorumlulu umuz...

Страница 6: ...1 Cleaning the pump 9 8 2 Frost protection 10 9 Technical data 11 10 Fault finding 12 11 Disposal 13 Warning Prior to installation read these installation and operating instructions Installation and...

Страница 7: ...1 Handle It is not necessary to fit the handle supplied on permanently installed pumps On portable pumps the handle can be fitted lengthwise or crosswise depending on the material variant 5 2 Ejector...

Страница 8: ...d a motor protective circuit breaker Carry out the electrical connection as shown in the diagram on the inside of the terminal box cover 6 1 Checking the direction of rotation three phase motors Arrow...

Страница 9: ...ugh with clean water immediately after use 8 1 Cleaning the pump It is only necessary to clean the pump if it does not work as intended and flushing it with clean water did not eliminate the problem T...

Страница 10: ...it plug pos 25 or ejector valve pos 25a Check that the ejector valve is in position 1 See fig 4 Tighten the plug or ejector valve using fingers only In orders for spare parts please mention the positi...

Страница 11: ...bar Inlet pressure At inlet pressures above 1 5 bar the discharge pressure must be at least 2 5 bar Supply voltage 1 x 220 240 V 50 Hz 3 x 220 240 380 415 V 50 Hz Insulation class F Enclosure class IP...

Страница 12: ...r a Pump is not filled with water Prime the pump See section 7 b Suction pipe blocked by impurities Clean the pump Check or replace the strainer in the suction pipe c Pump blocked by impurities Clean...

Страница 13: ...ermal switch in the motor has tripped due to overheating The thermal switch will cut in automatically when the motor has cooled sufficiently If the problem still persists check these two possible caus...

Страница 14: ...ial variant B TM04 2346 2308 Pump type Dimensions mm A B C JP 5 material variant A 300 364 240 JP 6 material variant A 300 401 240 TM04 2347 2308 Pump type Dimensions mm A B C JP 5 material variant B...

Страница 15: ...15...

Страница 16: ...OY GRUNDFOS Pumput AB Mestarintie 11 FIN 01730 Vantaa Phone 358 0 207 889 900 Telefax 358 0 207 889 550 France Pompes GRUNDFOS Distribution S A Parc d Activit s de Chesnes 57 rue de Malacombe F 38290...

Страница 17: ...421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS d o o landrova 8b SI 1231 Ljubljana rnu e Phone 386 31 718 808 Telefax 386 0 1 5680 619 E mail slovenia grundfos si South Africa GRUNDFOS PTY LTD Corn...

Страница 18: ...510 0112 ECM 1078675 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright G...

Отзывы: