4. Identification
Fig. 1
Nameplate
5. Installation
The pump must be installed horizontally.
When the suction pipe is longer than 10 metres or
the suction lift is greater than 4 metres, the diameter
of the suction pipe must be larger than 1". If there is
a suction lift, we recommend to fit a non-return valve
to the suction pipe.
If a hose is used as a suction pipe, it must be
non-collapsible.
To prevent solids from entering the pump, a filter can
be fitted to the suction pipe.
Make sure that the pump is not stressed by the
pipework.
Connect the discharge pipe to the pump discharge
port (T). See fig.
. H = maximum 7 metres.
Fig. 2
Pipe connection
Installation dimensions can be found on page
5.1 Handle
It is not necessary to fit the handle supplied on
permanently installed pumps.
On portable pumps the handle can be fitted
lengthwise or crosswise depending on the material
variant.
5.2 Ejector valve
The ejector valve is supplied separate with the
pump.
Remove the plug (V), see fig.
, and fit the ejector
valve into the hole.
TM
05
17
97
37
11
Pos. Description
1
Type
2
Model
3
Supply voltage
4
Maximum current
5
Frequency
6
Maximum pressure
7
Maximum head
8
Country of origin
9
Rated head
10
Enclosure class
11
Input power
12
Rated flow rate
13
Maximum ambient temperature
14
Maximum liquid temperature
15
Efficiency class
16
Production company
Type
Model
U
Imax
f
Pmax
Hmax
Hnom
IP
P1
Hz
MPa/Bar
m
m
W
A
V
Qnom
Tamb, max
Tliq, max
m /h
C
O
O
C
3
1
2
3
4
5
6
7
10
9
8
11
12
13
14
15
16
T
M
05
17
96
37
11
Note
The O-ring must be fitted to the ejector
valve.
Tighten the valve using fingers only.
Ma
x.
7