3.17 Installing a diaphragm pump

The diaphragm pump is optional.
1. Drill the outlet for the diaphragm pump. See 

section 

3.7 Drilling holes for the pipes

.

2. Fit the DN 40 socket seal in the opening for the 

diaphragm pump at the bottom of the tank. See 
figures 

21

 and 

22

.

3. Insert the pipe from the diaphragm pump into the 

outlet.

4. Secure the diaphragm pump and connect it to the 

building outlet pipe according to the installation 
and operating instructions of the pump.

3.18 Installing the controller

Mount the controller on a wall with screws through 
the mounting holes of the back plate.
The cable entries must point downwards, and the 
user interface must be easily accessible.
See the installation and operating instructions of the 
controller.

3.19 Electrical connection

3.19.1 Connecting the pump

Connecting the pump to a power socket

1. Lead the pump cable through the cable gland.
2. Fit the power plug on the cable. A Schuko plug is 

supplied with the product.

3. Insert the plug into a power socket.

Connecting the pump to a controller

1. Lead the pump cable through the cable gland.
2. Connect the pump cable to the controller. See the 

wiring diagram supplied with the controller.

3.19.2 Connecting the level sensor hose to the 

controller

Connect the level sensor hose to the pneumatic 
entry in the bottom of the controller. The hose is 
connected properly when it is pushed all the way in 
and locked in position.

3.19.3 Connecting an alarm float switch to the 

controller

1. Lead the cable of the float switch through one of 

the M20 cable glands in the bottom of the 
controller.

2. Connect the cable to the terminal for high-level 

alarm. See the installation and operating 
instructions of the controller.

3.20 Setting the controller before startup

LC 220

Select settings via the DIP switches. See the 
installation and operating instructions of the 
controller. 

LC 221

You must set the start level and rated current of the 
motor to be able to start the product. All other 
settings are preset.
1. Close the isolating valves.
2. Set the selector switches on the controller to 

"OFF".

3. Switch on the controller.
4. When the display shows "L_01", press [OK] to 

enter the start level menu.

5. Select the start level using the left and right 

arrows and press [OK]. See section 

7.1.1 Setting 

the start levels with a controller

.

6. Go to the rated current menu "L_02" using the 

left and right arrows and select the rated motor 
current [A] according to the nameplate of the 
pump motor.

You can change some factory settings. See the 
installation and operating instructions of the 
controller. 

DANGER

Electric shock

Death or serious personal injury
- Before starting any work on the product, 

make sure that the power supply has 
been switched off and that it cannot be 
accidentally switched on.

DANGER

Electric shock

Death or serious personal injury
- The protective earth (PE) of the power 

outlet must be connected to the 
protective earth of the product. The plug 
must have the same PE connection 
system as the power outlet.

DANGER

Electric shock

Death or serious personal injury
- The installation must be fitted with a 

residual current device (RCD) with a 
tripping current less than 30 mA.

DANGER

Electric shock

Death or serious personal injury
- The product must be connected to an 

external main switch with a minimum 
contact gap of 3 mm (0.12 inch) in all 
poles.

LC 220

LC 221

QR

98

503

25

2

QR

98

503

25

3

http://net.grundfos.com/

qr/i/98503252

http://net.grundfos.com/

qr/i/98503253

Содержание DUOLIFT APB Series

Страница 1: ...UNOLIFT DUOLIFT Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...he pump 9 3 13 Installing the pump connecting pipes 10 3 14 Installing the level sensor tube 12 3 15 Installing an alarm float switch 12 3 16 Installing the outlet pipes 12 3 17 Installing a diaphragm...

Страница 3: ...provided If the above is not fulfilled Grundfos can refuse to accept the pump for service Possible costs of returning the pump are to be paid by the customer The safety declaration can be found at th...

Страница 4: ...apter 2 2 2 Stainless steel clamp 2 2 2 Flexible connecting tube 50 1 1 1 Elbow 90 1 1 Flange 50 1 Screw for flange 4 Washer for flange 8 Nut M16 for flange 4 O ring 50 for flange 1 Unilift KP Double...

Страница 5: ...d must be above street level See fig 2 Surface water must not be discharged into the lifting station inside the building Collect and discharge surface water outside the building Install a non return v...

Страница 6: ...aterial resulting in a shorter life The product is designed for indoor operation If installed outside the lifting station must be placed in a closed pit The tank can be flooded and may be installed in...

Страница 7: ...es 3 5 Positioning the product Position the tank so that all components are easily accessible during operation and maintenance 3 6 Installing the tank Fix the tank to the floor to prevent uplift and t...

Страница 8: ...75 mm and with clamps A flexible pipe connection with clamps is available as an accessory By means of a PP double nipple with an inner diameter of 75 mm The nipple must comply with EN 1451 3 11 Conne...

Страница 9: ...sure that the float switch if any can move freely Unilift CC KP APB Position the pump between the three positioning dots at the bottom of the tank so that it stays in place during operation See figur...

Страница 10: ...nections 1 Assemble the connecting pipe outside the tank except for the nut See pos 1 in fig 11 2 Connect the connecting pipe to the pump in the tank 3 Connect the connecting pipe to the outlet of the...

Страница 11: ...English GB 11 TM05 9633 3913 TM05 9632 3913 Fig 13 Unilift AP35B AP50B Fig 14 SEG x4...

Страница 12: ...tie Make sure that there is a free cable length of minimum 70 mm Make sure that the float switch can move freely from its lowest position to its highest position 2 Tighten the cable tie 3 Drill a hol...

Страница 13: ...ith a non return valve The adapter Rp 2 R 1 1 2 for Duolift SEG is not shown on the drawing TM06 6220 3913 TM06 6512 1816 Fig 17 Duolift CC KP Fig 18 Unolift CC KP TM05 9635 3913 TM05 9634 3913 Fig 19...

Страница 14: ...terminal for high level alarm See the installation and operating instructions of the controller 3 20 Setting the controller before startup LC 220 Select settings via the DIP switches See the installat...

Страница 15: ...d level in the tank up to the start level and check that the pumps start and stop at least twice 5 Storing the product The tank must not be exposed to direct sunlight UV light can affect the propertie...

Страница 16: ...We recommend that you connect a diaphragm pump to the tank It is a positive displacement pump which can be operated manually It can be used to drain the tank before service or during power cuts The t...

Страница 17: ...e the number of start stops of the pumps A too high start level however may increase the backflow in the inlet pipe and thus increase the risk of deposits in the inlet pipe The figures below show the...

Страница 18: ...start and stop levels by adjusting the free cable length L Fig 25 Example of start and stop levels for Unilift CC We recommend start and stop levels corresponding to a cable length between the minimum...

Страница 19: ...and in commercial buildings four times a year We recommend that you enter a maintenance contract with Grundfos to ensure a consistent operational safety of the system Regular checks of the system must...

Страница 20: ...ontroller 11 4 Dimensions and weights The weight applies to the tank only WARNING Biological hazard Death or serious personal injury Wear protective gloves close the isolating valves and drain the tan...

Страница 21: ...2 It may be necessary to adjust the cable length See section 7 1 Setting the start levels b The pump cable is defective Repair or replace the cable 2 The pump does not stop a The float switch is bloc...

Страница 22: ...Appendix 22 Appendix 1 Fig 1 Unolift 270 Duolift 270 TM06 1067 1514...

Страница 23: ...Appendix 23 Fig 2 Duolift 540 TM06 1066 1514...

Страница 24: ...1 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 013...

Страница 25: ...na 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa GRUNDFOS...

Страница 26: ...029 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2018 G...

Отзывы: