English (GB)
9
3.12 Installing the pump
Pumps with float switches
Adjust the cable length of the float switch before you
install the pump. See section
.
1. Remove the plug from the pump cable. You may
need to cut the cable.
2. SEG: Fit the foot extensions. See fig.
3. Position the pump in the tank.
Make sure that the float switch, if any, can move
freely.
Unilift CC, KP, APB:
Position the pump between the three positioning
dots at the bottom of the tank so that it stays in
place during operation. See figures
.
SEG: The pump weight ensures that the pump
stays in place.
4. Lead the pump cable through the cable gland of
the tank.
5. Tighten the cable gland.
Fig. 8
Fitting the foot extensions on the SEG
pump
Fig. 9
Correct position of Unilift CC and KP
pumps
Fig. 10
Correct position of Unilift APB pumps
TM
02 657
1 21
16
T
M
06
59
65
03
16
TM
06 59
66 031
6
Содержание DUOLIFT APB Series
Страница 1: ...UNOLIFT DUOLIFT Installation and operating instructions GRUNDFOS INSTRUCTIONS...
Страница 11: ...English GB 11 TM05 9633 3913 TM05 9632 3913 Fig 13 Unilift AP35B AP50B Fig 14 SEG x4...
Страница 22: ...Appendix 22 Appendix 1 Fig 1 Unolift 270 Duolift 270 TM06 1067 1514...