3. Installing the product
DANGER
Falling objects
Death or serious personal injury
‐
Fasten the pump securely to a solid
and even foundation according to the
specifications stated in the installation
and operating instructions.
3.1 Mechanical installation
WARNING
Contamination when pumping drinking
water
Death or serious personal injury
‐
Before the pump is used for supplying
drinking water, flush the pump thor-
oughly with clean water.
‐
Do not use the pump for drinking water
if the internal parts have been in con-
tact with particles or substances not
suitable for water intended for human
consumption.
3.1.1 Lifting the product
WARNING
Falling objects
Death or serious personal injury
‐
Do not use the motor eyebolts to lift the
entire pump if the pump is fitted with a
motor of another make than Grundfos
MG and MGE.
‐
Follow the lifting instructions.
‐
Use lifting equipment which is ap-
proved for the weight of the product.
‐
Persons must keep a safe distance to
the product during lifting operations.
‐
Wear personal protective equipment.
For lifting instructions, see section Lifting the product.
Related information
3.1.2 Drive-end motor bearing
Make sure to use the correct type of drive-end (DE) motor bearing for the bare-shaft pump. Please check the
specific pump range and pump version stated on the nameplate and select the corresponding DE bearing.
DE bearing
CR 1-64 pump range
DE bearing
CR 95-255 pump range
Pump version
1)
Deep-groove ball
bearing
(62/63xx)
Angular contact
bearing
(73xx)
Deep-groove ball
bearing
(62/63xx)
Angular contact
bearing
(73xx)
A Standard pump
0.37 - 3 kW
4-45 kW
75-200 kW
5.5 - 55 kW
T
Pump with thrust
handling device
(THD)
2)
-
-
-
Not allowed
Z
Pump with bearing
flange
2)
0.37 - 45 kW
Not allowed
5.5 - 200 kW
Not allowed
1)
Refer to the codes for pump version described in the section on type key.
2)
Factory product variants (FPV).