3.1.10 Flange forces and torques
If not all loads reach the maximum permissible value stated in the tables below, one of these values may exceed
the normal limit. Contact Grundfos for further information.
TM040346
Flange forces and torques
Y-direction:
Inlet or outlet
Z-direction:
Direction of chamber stack
X-direction:
90 ° from inlet or outlet
The following tables represent the values that apply according to the material quality.
Force limits for CR pumps
Flange, DN
[mm]
CR
Force, Y-direction
[N]
Force, Z-direction
[N]
Force, X-direction
[N]
100
95
1256
1013
1125
150
125 and 155
1875
1519
1688
200
185, 215 and 255
2513
2025
2250
Force limits for CRN pumps
Flange, DN
[mm]
CRN
Force, Y-direction
[N]
Force, Z-direction
[N]
Force, X-direction
[N]
100
95
2513
2025
2250
150
125 and 155
3750
3038
3375
200
185, 215 and 255
5025
4050
4500
Torque limits for CR pumps
Flange, DN
[mm]
CR
Torque, Y-direction
[Nm]
Torque, Z-direction
[Nm]
Torque, X-direction
[Nm]
100
95
375
475
625
150
125 and 155
625
775
1000
200
185, 215 and 255
900
1075
1375