8

Repeat the procedure until the right cut-in and cut-
out pressures have been obtained.

Note:

 The cover must be fitted to the pressure 

switch every time the electricity supply is switched 
on. 

Pressure variations in the system can be reduced by 
reducing the differential pressure to a minimum. Set 
the differential pressure by means of the screw B, 
see fig. 2. 

5. Operation and maintenance

5.1 Checking the tank precharge pressure 

To ensure reliable and correct operation, including 
the frequency of stop/starts, the precharge pressure 
of the diaphragm tank should be checked regularly 
(at least once a year). The precharge pressure can 
be measured with, e.g. a tyre gauge. 

5.2 Frost protection 

If there is any danger of frost, the tank and the pump 
should be emptied. 

6. Technical data and 

operating conditions

Supply voltage:

See pages 92 and 93.

CH:

• 1 x 220-240 V –10%/+6%, 50 Hz, PE.

• 3 x 220-240 V –10%/+6%, 50 Hz, PE.

• 3 x 380-415 V –10%/+6%, 50 Hz, PE.

• 1 x 110 V –10%/+10%, 60 Hz, PE.

• 1 x 220 V –10%/+10%, 60 Hz, PE.

JP 5:

• 1 x 220-230 V –10%/+6%, 50 Hz, PE.

• 1 x 230-240 V –10%/+6%, 50 Hz, PE.

• 3 x 220-240 V –10%/+6%, 50 Hz, PE.

• 3 x 380-415 V –10%/+6%, 50 Hz, PE.

JP 6:

• 1 x 220-240 V –10%/+6%, 50 Hz, PE.

• 3 x 380-415 V –10%/+6%, 50 Hz, PE.

• 3 x 220-240 V –10%/+6%, 50 Hz, PE.

Enclosure class:

CH:

IP 54.

JP:

IP 44. 

Sound pressure level:

The sound pressure level of the pumps is lower than 
the limiting values stated in the EC Council Directive 
2006/42/EC relating to machinery.

Maximum operating pressure: 

Diaphragm tank:

See nameplate. 

JP pumps:

6 bar. 

CH pumps:

10 bar. 

Maximum liquid temperature: 

Diaphragm tank:

See nameplate. 

JP pumps:

+40°C. 

CH pumps:

+90°C. 

Ambient temperature: 

M55°C. 

7. Disposal

Disposal of this product or parts of it must be carried 
out according to the following guidelines:

1. Use the local public or private waste collection 

service.

2. In case such waste collection service does not 

exist or cannot handle the materials used in the 
product, please deliver the product or any haz-
ardous materials from it to your nearest Grundfos 
company or service workshop.

Before start-up, the system must be 
flushed through with clean water and 
drained to remove possible impurities in 
the system.

If the liquid temperature e68°C, 
the booster set must cool before any main-
tenance work is carried out.

Care should be taken to ensure that per-
sons cannot come into contact with the 
booster set during operation, e.g. by 
installing a guard.

Subject to alterations.

Содержание CH

Страница 1: ...CH JP GRUNDFOS INSTRUCTIONS Installation and operating instructions ...

Страница 2: ...0335 1 2002 e EN 60335 2 41 2003 Directiva EMC compatibilidade electromagnética 2004 108 CE Normas utilizadas EN 61000 6 2 e EN 61000 6 3 Δήλωση Συμμόρφωσης Εμείς η Grundfos δηλώνουμε με αποκλειστικά δική μας ευθύνη ότι τα προϊόντα CH και JP στα οποία αναφέρεται η παρούσα δήλωση συμμορφώνονται με τις εξής Οδηγίες του Συμβουλίου περί προσέγγισης των νομοθεσιών των κρατών μελών της ΕΕ Οδηγία για μηχ...

Страница 3: ...kona država članica EU Direktiva za mašine 2006 42 EC Korišćeni standardi EN 809 1998 i EN 60204 1 2006 Direktiva niskog napona 2006 95 EC Korišćeni standardi EN 60335 1 2002 i EN 60335 2 41 2003 EMC direktiva 2004 108 EC Korišćeni standardi EN 61000 6 2 i EN 61000 6 3 Declaraţie de Conformitate Noi Grundfos declarăm pe propria răspundere că produsele CH şi JP la care se referă această declaraţie ...

Страница 4: ...4 ...

Страница 5: ...ς 26 Installatie en bedieningsinstructies 29 Monterings och driftsinstruktion 32 Asennus ja käyttöohjeet 35 Monterings og driftsinstruktion 38 Instrukcja montażu i eksploatacji 41 Руководство по монтажу и эксплуатации 46 Szerelési és üzemeltetési utasítás 52 Navodila za montažo in obratovanje 56 Montažne i pogonske upute 60 Uputstvo za montažu i upotrebu 64 Instrucţiuni de instalare şi utilizare 6...

Страница 6: ... be located and connected in accordance with local regulations The motor of the booster set must not be covered as an adequate supply of cool air must reach the motor cooling fan 3 3 Pipework The pipes connected to the booster set must be of adequate size Note If the booster set has no non return valve a non return foot valve must be fitted in the suction pipe of the pump 3 4 Priming Before starti...

Страница 7: ...operating pressure of the pump and tank Remove the cover from the pressure switch to reveal the adjusting screws see fig 2 Fig 2 If another pressure switch setting is desired proceed as follows Setting the cut in pressure 1 Turn the screw B clockwise to reduce the cut in pressure Turn the screw B counter clockwise to increase the cut in pressure The differential pressure range is widened and narro...

Страница 8: ...0 Hz PE JP 6 1 x 220 240 V 10 6 50 Hz PE 3 x 380 415 V 10 6 50 Hz PE 3 x 220 240 V 10 6 50 Hz PE Enclosure class CH IP 54 JP IP 44 Sound pressure level The sound pressure level of the pumps is lower than the limiting values stated in the EC Council Directive 2006 42 EC relating to machinery Maximum operating pressure Diaphragm tank See nameplate JP pumps 6 bar CH pumps 10 bar Maximum liquid temper...

Страница 9: ...87 CH TM00 2825 3504 4 3 2 5 11 9 8 7 1 6 10 ...

Страница 10: ...88 JP TM00 2826 3504 7 8 6 9 3 4 1 2 5 11 10 ...

Страница 11: ...89 CH TM00 2827 0394 8 7 5 4 6 3 2 1 ...

Страница 12: ...90 JP TM00 2828 0394 8 7 5 4 6 3 2 1 ...

Страница 13: ...91 TM02 6039 0605 ...

Страница 14: ...94 TM00 2830 0394 TM00 2831 0394 TM00 2832 0394 TM00 2833 0394 TM00 2834 0394 TM00 2835 0394 1 x 220 V 60 Hz 1 x 110 V 60 Hz 1 x 220 V 60 Hz 1 x 220 240 V 50 Hz 1 x 220 240 V 50 Hz 3 x 380 415 V 50 Hz 3 x 220 240 V 50 Hz ...

Страница 15: ...36 0394 TM00 2834 0394 TM00 2835 0394 1 x 220 230 V 50 Hz 1 x 230 240 V 50 Hz 3 x 380 415 V 50 Hz 3 x 220 240 V 50 Hz TM00 2833 0394 TM00 2834 0394 TM00 2835 0394 1 x 220 240 V 50 Hz 3 x 380 415 V 50 Hz 3 x 220 240 V 50 Hz ...

Страница 16: ... 1391 Telefax 81 35 448 9619 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava ielā 60 LV 1035 Rīga Tālr 371 714 9640 7 149 641 Fakss 371 914 9646 Lithuania GRUNDFOS Pumps UAB Smolensko g 6 LT 03201 Vilnius Tel 370 52 395 430 Fax 37...

Страница 17: ...www grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 981763 0110 183 Repl 981763 0205 ...

Отзывы: