3
COMPONENT LIST
1
ART. NO.
A
R
T
. NO
.
3
4
ART. NO.
REF. NO. PART NO
PART DESCRIPTION
QUANTITY
1
Not available as spare
Pump tube assembly
1
2
Not available as spare
Bucket Assembly (in 12 or 16 Litre capacity)
1
3
KIT/BLP/1293
Vinyl Hose (with Adaptor, Clamp, Steel Spout)
1
4
HND/BLP/321
Lever Handle
1
Delivery Spout
Adaptor
Clamp
Hose
2
Problem
Possible Cause
Corrective Action
Pump fails to prime
Priming is needed
Pour a few drops of the fluid being dispensed
into the pump outlet.
Start the pump by moving the lever with
several quick strokes
Pump does not dispense the fluid
Blockage in the suction line
Remove the pump from the bucket and ensure
that suction tube & non-return valve is free of
any blockage
TROUBLESHOOTING
SPECIFICATIONS
OLP-12
OLP-16
Discharge Rate
Upto 125 ml (4.64 oz.) per stroke
Mechanism
Lever Action
Hose Length
48”
Outlet Size
1/4” NPT
Drum Cover Dia.
8.81” (224 mm)
Container Size
12 Litres / 3.17 Gal
16 Litres / 4.23 Gal
Pump Length
18” (450 mm)
20.62” (524 mm)