![GrowSpan PGFLSAXXFCW0063 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/growspan/pgflsaxxfcw0063/pgflsaxxfcw0063_manual_2270665008.webp)
8
2-Layer Film Install
Revision date: 04.17.20
Install Flashing (PGFLSAXXFCW0063)
6. Place prepared flashing against top of end rafter with cut surface against end panels.
7. Using 108553 wafer head screws spaced at 16" on-center intervals, secure flashing to top of end rafter.
8. Prepare another piece of flashing and attach to rafter. Overlap end of first section with end of second section of flashing by approximately 2" to 3" if desired.
Use hand clamps to help hold and bend flashing into position.
9. Continue installing flashing and work down to ground.
INSTALL FLASHING — CONTINUED
Flashing
6
7
Flashing
ATTENTION:
Be mindful of where to cut last section of flashing as you near end of end rafter. You may not need to cut every 12" to install final section.
10. Once one end is complete, attach flashing to remaining end rafter.
11. Continue with next procedure.
Cross Section of End Rafter,
End Panel, and Flashing.
Top of End Rafter
End
Rafter
Polycarbonate End Panel
Foil T
ape
108553 Screw
ATTENTION:
Actual frame and
door design may differ. Flashing
installation is similar.