GrowSpan 106363 Скачать руководство пользователя страница 21

21

GROWSPAN

 COLD FRAMES & GREENHOUSES

Revision date: 05.08.18

PANEL A DIAGRAMS

Flat Side Up

UV-Protected 

Surface Up

Handle

DO NOT

 install profile along the 

panel edge opposite where the 

handle is attached. 

Panel A Only

.

ATTENTION

: Install all profile for 

Panel A with the flat side up as 

shown. UV-protected side of the 

polycarbonate panel is 

always

 

installed toward the sun.

ATTENTION

: Cut all profile for this 

panel so that it is installed as shown 

in these diagrams.

UV-Protected surface 

is always installed 

toward the sun.

Edge of Panel

Edge of Panel

Center handle and 

secure with Tek 

Screw (#FA4472B)

Felt Tape

44-3/4"

Top View of the Panel A

Содержание 106363

Страница 1: ...S Revision date 05 08 18 GrowSpan Heavy Duty Commercial Cold Frame STK DIMENSIONS 106363 4 W x 23 H x 7 9 L Photo may show a different but similar model 2018 GrowSpan All Rights Reserved Reproduction...

Страница 2: ...revent property damage and serious personal injury the assembled cold frame must be anchored to the site LOCATION Choosing the proper location is an important step before you begin to assemble the col...

Страница 3: ...5 Assemble the frame components in the order they are presented in these instructions 6 Read the Safety and the Cold Frame Care and Maintenance information at the end of these instructions 7 Complete...

Страница 4: ...ing FA4472B Tek Screw 102921B FA4474B Tek Screws and Neo bonded washers QH1330 Angle Bracket 104548 End Cap Profile Doors Fans Vents 113236z096 Aluminum H Channel Profile NOTE Install center bolt chan...

Страница 5: ...not allow channel side out installation Use the diagrams on this page to install H channel with flat side facing out ATTENTION Use only 1 1 2 Tek screws to attach H channel to building frame Do not u...

Страница 6: ...and install sliding cover panels 5 Install safety straps and cover hardware GrowSpan Heavy Duty Commercial Cold Frame S15P012 S15P092 102923 A second 102923 is used for the cold frame cover QH1330 S1...

Страница 7: ...2 and the angle brackets QH1330 attach the sidewall corner tubes NOTE The 18 lengths are positioned to the back and the 12 lengths are positioned to the front S15P018 S15P012 S15P012 S15P018 HINT Atta...

Страница 8: ...Locate the four 4 angle iron corner ground stakes 105232 and the remaining frame assembly 102923 to use as a guide for driving the stakes NOTE If you are positioning the cold frame on a surface such a...

Страница 9: ...to the stakes if used set and center the remaining frame 102923 on top of the assembled cold frame NOTE The cross brace of the cover frame is slightly off center While standing in front of the cold f...

Страница 10: ...instructions and the photos in this section to properly account for the installation requirements of the profile 3 Install the profile on each panel NOTE A small piece of tape not included can be used...

Страница 11: ...ends beyond the edges of the cut panels Refer to the photos before cutting the panels and profile CUT AND ASSEMBLE THE POLYCARBONATE PANELS CONTINUED ATTENTION This profile 104548 is installed on all...

Страница 12: ...line shows the edge of the panel Vertical profile sections run between the horizontal lengths ASSEMBLE THE TWO 2 SLIDING PANELS FOR THE COVER Panel A and Panel B are assembled differently Consult the...

Страница 13: ...profile for the panel When installed correctly the profile will appear as shown below for Panel A Assemble Panel B The steps to install the profile on Panel B are slightly different from those of the...

Страница 14: ...the procedures up to this point were followed the cover frame has been attached to the main cold frame and the sliding panels are prepared IMPORTANT NOTE For this procedure the small square or opening...

Страница 15: ...ng the edge of the frame Cover Frame Back of Frame The profile installed above acts as guide tracks for the sliding cover panels Diagram may differ slightly from the actual frame White dashed line sho...

Страница 16: ...screws of the long sections of cover frame profile to allow the tape to expand and retry the doors NOTE When properly installed there will be a noticeable drag between the panels when they are slid op...

Страница 17: ...e and cover frame along the sides to prevent damage to plants on the inside of the frame 1 Raise the cover and lock it in the open position using the locking hole in the support arm as shown 4 Flip th...

Страница 18: ...st remain secured at all times using the support arm and wing nuts Wing nuts must be tight to lock the support arm in place WARNING DO NOT prop the cover open Serious injury may occur if the prop slip...

Страница 19: ...AME Remove debris and objects that can accumulate on the cold frame Use tools that will not damage the polycarbonate panels when removing debris and when trimming around the outside of the cold frame...

Страница 20: ...18 QUICK START GUIDE Commercial Cold Frame with Sliding Cover Panels ASSEMBLY NOTE Install Tek screws using a clutched drill driver running approximately 750 RPM while applying approximately 50 lbs of...

Страница 21: ...TTENTION Install all profile for Panel A with the flat side up as shown UV protected side of the polycarbonate panel is always installed toward the sun ATTENTION Cut all profile for this panel so that...

Страница 22: ...urface up UV protected side of the polycarbonate panel is always installed toward the sun ATTENTION Cut all profile for this panel so that it is installed as shown in these diagrams Edge of Panel Edge...

Страница 23: ...TOP FRONT AND RIGHT SIDE Dashed line shows the edge of Panel A under Panel B NOTE Position the H Channel between each long horizontal profile section Install with flat side out Use two 2 FA4474B Tek...

Страница 24: ...08 18 PANEL LOCATION DIAGRAM BACK AND REMAINING SIDE NOTE Position the H Channel between each long horizontal profile section Install with flat side out Use two 2 FA4474B Tek screws View shows the co...

Страница 25: ...DOING SO WILL MAKE THE FILM DIFFICULT IF NOT IMPOSSIBLE TO REMOVE DAMAGE TO PANELS MAY OCCUR IF STACKED IN DIRECT SUNLIGHT PROTECT STACKED PANELS FROM DIRECT SUNLIGHT ATTENTION Install all UV protect...

Страница 26: ...1 2 13 1 2 C D 45 1 2 Dimensions for Panel C are the same as Panel D ATTENTION Install all UV Protected surfaces to the outside of the cold frame See previous page to determine which panels to cut fro...

Страница 27: ...245 9881 for additional information or to purchase the opener Solar Powered Opener Not included Must be purchased separately Views show the installed opener from the outside of the cold frame Views sh...

Отзывы: