60
AC short-circuit protection
Integrated
Ground fault monitoring
Integrated
Grid monitoring
Integrated
Anti-islanding protection
Integrated(
Active Frequency Drift
)
Residual-current monitoring
unit
Integrated
General data
Dimensions (W / H / D) in
mm
274*254*138
Weight
6.0 kg
6.2 kg
Operating temperature range
–25 °C ... +60 °C
Noise emission (typical)
≤ 25 dB(A)
Altitude
4000m
Internal consumption at night
<0.5W
Topology
Non-isolated
Cooling
Natural convection
Protection degree
IP65
Relative humidity
0~100%
DC connection
VP-D4/H4 (opt)
AC connection
AC connector
Interfaces
Display
OLED+LED
RS485/USB
Integrated
WIFI/GPRS/4G/LAN/ RF
Optional
Warranty:5/10 years
Yes/ Optional
14.2 DC &AC connector info
DC connector
VP-D4(
Dongguan
Vaconn Electronic
Technology
)
Amphenol Helios
H4 (opt)
-
AC connector*
VPAC06EP-3P(SC)S
EN032-1128-1001
*
Only for Australia market.
14.3 Torque
Enclosure lid screws
12kgf
·
cm
AC terminal
6kgf
·
cm
Signal terminal
4kgf
·
cm
Safety screw
12kgf
·
cm
Additional ground screws
12kgf
·
cm