59
Max. DC voltage
500V
550V
Start voltage
50V
80V
Min.
operating voltage
50V
65V
Nominal voltage
360V
MPP voltage range
50V-500V
65V-550V
No. of MPP trackers
1
No. of PV strings per MPP
trackers
1
Max. input current per MPP
trackers
13A
Max. short-circuit current per
MPP trackers
16A
Output data(AC)
Rated output power
2000W
2500W
3000W
3300W
Rated apparent power
2000VA
2500VA
3000VA
3300VA
Max. AC apparent power
2000VA
2500VA
3000VA
3300VA
Nominal AC voltage/range*
230/
180~280V
AC grid frequency/range
50-60Hz/44-55Hz;54-65Hz
Rated output current
8.7A
10.9A
13A
14.3A
Max. output current
9.5A
11.9A
14.3A
14.3A
Initial short-circuit AC current
8.7A
10.9A
13A
14.3A
Inrush current
<10A
Max output fault current
66A
Max output overload
protection
16A
Backfeed current
0A
Power factor(@nominal
power)
>0.99
Adjustable power factor
0.8leading… 0.8lagging
THDi
<3%
AC grid connection type
Single phase
Overvoltage category
PV:II AC:III Others:I
Efficiency
Max. efficiency
97.6%
97.6%
97.6%
97.6%
Euro-eta
97%
97%
97.1%
97.1%
Protection devices
DC reverse-polarity
protection
Integrated
DC switch
Integrated
DC Surge protection
Type II
Insulation resistance
monitoring
Integrated
AC surge protection
Type III