MELBURY HE 3800-10000 -
Installation, Use and Maintenance
Page 14 / 36
410821-V11
2.4. Dimensions of custom made models for Melbury HE
The following custom made models are available on
request. They are however subject to different delivery
times!
2.4.1. Vertical flue connection
CAUTION:
The vertical smoke nozzles are not made on the Melbury HE.
figure 3 – Melbury HE 3800-1000
Melbury HE
3800 4500 5400 6300 7400 8600 10000
Flue outside diameter
e mm
550
600 650 700 750
850 900
Flue position
n
1
mm
4235
4477 4872 5277 5722 6254 6849
Overall length
L
1
mm
4695
4960 5380 5850 6320 6900 7520
Catwalk length
n mm
3940
4157 4527 4905 5325 5807 6377
The other dimensions are identical to those of the
standard range.
!