Important:
• If an array of several devices is installed, a valve assembly must be
fi
tted to each tank and
a non-return
fl
ap on the overall supply pipe.
• If the pressure of the distribution network exceeds 5 bar, a pressure reducer must be
fi
tted
to the overall supply pipe.
• If metal piping is used, use a cast-iron sleeve or a dielectric pipe joint (brass connectors
are prohibited).
4.3. Hydraulic safety installation
4.3.1. Safety units:
Safety units are always installed on the cold water inlet to the tank. When installing the unit,
respect the
fl
ow direction indicated by arrows on the body of the security unit.
No non-return valve or
fl
ap should ever be
fi
tted between the safety valve or safety unit
and the tank.
!
4.3.2. Safety valves:
The safety valves are
fi
tted to the tank inlet using a T (see diagram below).
SAFETY UNIT
SAFETY VALVE
On cold water inlet only
On tank inlet
1 single G 1¨ unit
1¼¨ kit with 2 G 1¨ units
Valve diameter
≥
tank connector diameter
Safety valve/non-return
fl
ap/valve
A non-return
fl
ap preceded by a valve must be
fi
tted to the cold water inlet if the tank is
equipped with a safety valve. To avoid scaling of these components, operate the safety unit
at least once a month by moving its controls to various positions.
5. ELECTRIC
ELEMENTS
For the CORFLINOX direct-immersion option
It is possible to add 3 to 12 kW direct-immersion heating elements according to the following
recommended combinations:
Immersion heating
element
Recommended combinations
3 kW tri 230 / 400 V
300 to 910 L
6 kW tri 400 V
300 to 910 L
12 kW tri 400 V
750 to 910 L