GLDM 64.1 Technical Manual rev. 1.30 February
2020
Page 31 of 50
Examples:
Master (PC / PLC) sends
Slave (GLDM) responds
Meaning
NS_0_0
D:6410
The device type is GLDM 64.1
NS_0_1
B 115200
The serial channel baud rate is 115200
NS_0_2
A:000
The serial channel address is 0
NS_0_1_230400
OK
Set the serial channel baud rate to
230400
8.10.4. BR Baud Rate
– Serial channel
[ n.a. ]
With this command the following baud rates can be setup: 9600, 19200, 38400, 57600, 115200, 230400 and
460800 Baud.
Master (PC / SPS) sends
Slave (GLDM 64.1)
responds
Meaning
BR
B 115200
Request: 115200 Baud (= factory default)
BR230400
OK
Setup: 230400 Baud
Factory default:
115200 baud
Note:
After editing the baud rate you first have to save the changes (command WP) and then restart the
device.
8.10.5. DX Full Duplex
– Serial channel
[ n.a. ]
Master (PC / SPS) sends
Slave (GLDM 64.1)
resp.
Meaning
DX
X:001
Request: DX = 1 (Full duplex, factory default))
DX1
OK
Setup: DX = 1 (Full duplex)
Not
e: The GLDM 64.1
always
operates in full duplex mode.