Safety notes
Avoid danger due to damaged external transformer
connection cables. In the case of damage, the
external transformer connection cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug power supply is only suitable for indoor use.
• The plug-in connectors must
not
be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
Application
Can be used in conjunction with:
• pressurised storage heaters.
Use in conjunction with unpressurised storage heaters
(displacement water heaters) is
not
possible.
Specifications
• Max. flow
8.2 L/min or 2.2 gpm / 60 psi
• Flow pressure
- min.
7.25 psi
- recommended
14.5 - 72.5 psi
- greater than 72.5 psi, fit pressure
reducing valve
• Max. operating pressure
145 psi
• Test pressure
232 psi
• Temperature
- max. (hot water inlet)
176
°
F
• Voltage supply:
120 V AC, 50/60 Hz
(plug power supply 120 V AC/6 V DC)
• Power consumption:
9 VA
• Radio frequency:
2.4332 GHz
• Transmitter power:
< 0.05 mW
• Emergency voltage supply: 6 V lithium battery (type CR-P2)
• Pre set panel battery:
3 V lithium battery (type CR 2032)
• Automatic safety shut-off (factory setting):
60 sec.
• Type of protection:
- Faucet
IP 66
- Plug power supply
IP 40
- Battery unit
IP 66
- Operating panel
IP 69K
- Pre set panel
IP 57
• Battery indicator:
Symbol in the display
• Water connection
cold - RH
hot - LH
Note
Major pressure differences between hot and cold water supply
should be avoided.
Electrical test data
• Software class:
B
• Contamination class:
2
• Rated surge voltage:
2500 V
• Temperature for ball impact test:
212 °F
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage
and rated current.
Approval and conformity
This device complies with part 15 of the FCC Rules (USA) and
with the RSS of the IC Rules (Canada).
Operation is subject to the following two conditions:
This device may not cause harmful interference, and this
device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party
responsible for compliance may void the user’s authority to
operate the equipment.
Installation
Grease O-rings with the special grease supplied
prior to installation.
Electrical installation
Electrical installation work must only
be performed by a qualified electrician. This
work must be carried out in accordance with
the regulations according to IEC 364-7-701-1984
(corresponding to VDE 0100 Part 701) as well
as all national and local regulations.
Install operating panel
, see fold-out page II, fig. [1].
Note the seat of the recess for the cable, see detail.
Install function unit and thermistor
,
see figs. [2] and [3].
Install spout
,
see fig. [4].
Attach battery unit
,
see fig. [5].
Install pre set panel
, see figs. [6] and [7].
Insert batteries with correct polarity.
Install pop-up drain (65 818)
, see fold-out page I, ensure that
flange of pop-up drain is sealed.
Connect voltage supply
,
see fig. [9].
Settings during a power failure / when changing batteries
No settings saved by the user will be lost when changing
the batteries or in the event of a power failure.
Flush piping system prior and after installation of faucet
thoroughly!
Connect faucet
, see figs. [8] and [9].
The cold water supply must be connected on the right,
hot water supply on the left.
If the connections are transposed, the water routes
can be swapped in setting mode under
Calibrate
.
Open hot and cold water supply and check connections
for leakage.
Operation
Using the operating panel
Start/Stop button
Starts and stops the faucet at a preset temperature
(factory setting 100 °F) and full flow rate.
Pause button
Interrupts the flow of water (temperature arrow on
operating panel orange). The flow is resumed by
pressing the button again.
The faucet switches off automatically after a preset
time (factory setting 60 sec.).
Temperature
Increases (red arrow, left) or decreases (blue arrow,
right) the water temperature.
Volume
Increases
or decreases the flow rate
in four stages in total.