background image

1

GB

GB

Application

Can be used in conjunction with:
•  Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement 
water heaters) is 

not

 possible.

The water filtrate is classified as Category 2 according 
to EN 1717.

Safety notes

Avoid danger due to damaged power cords. In the 
case of damage, the control unit must be replaced by 
the manufacturer or his customer service department 
or an equally qualified person.

• The filter system 

must always

 be operated with cold water 

of foodstuff grade.

• The control unit and plug must 

not

 be directly or indirectly 

sprayed with water when cleaning.

•  The control unit 

must

 be connected to a permanent power 

supply.

•  At the installation location, the filter system 

must

 be 

protected against mechanical damage, heat and direct 
sunlight. 

Do

 

not

 install near heat sources or an open fire.

•  Installation of the fitting with filter cartridge is 

only permitted

 

in frost-free rooms.

• Use 

only genuine replacement parts and accessories

The use of other parts will result in voiding of the warranty 
and the CE identification.

Technical data

Electrical data:

• Voltage supply: 

100 - 240 V AC / 50/60 Hz

• Power consumption: 

9 W

• Standby power loss: 

 < 1.0 W

• Type of protection

– Control unit:

IP 68

– Mains plug:

IP 40

Sanitary data:

• Flow pressure:

– min.

0.1 MPa

– recommended

0.2 – 0.5 MPa

• Operating pressure

– Fitting:

max. 0.8 MPa

– Filter cartridge and filter head:

0.2 – 0.8 MPa

•  Test pressure of fitting:

1.6 MPa

If static pressures exceed 0.5 MPa, a pressure-reducing valve 
must be installed.
Avoid major pressure differences between hot and cold water 
supply.
•  Flow rate at 0.3 MPa flow pressure

– Fitting (tap water):

approx. 9 l/min

– Filter cartridge (GROHE Blue

®

 water):

approx. 3.5 l/min

•  Ambient temperature:

4 – 32 °C

• Temperature

– Hot water inlet:

max. 70 °C

– Recommended (energy saving):

 60 °C

•  Adjustable bypass, factory setting:

 2

•  Filter capacity at bypass setting 2

(Carbonate hardness 10 - 24 °KH):

max. 750 liters

corresponds to max. 12 months

• Water connection:

cold - blue

hot - red

Electrical test data

• Software class:

A

• Contamination class:

2

•  Rated surge voltage:

2,500 V

•  Temperature for ball impact test:

100 °C

The test for electromagnetic compatibility (interference 
emission test) was performed at the rated voltage and rated 
current.

Approval and conformity

The conformity declarations can be obtained from the following 
address:

GROHE Deutschland Vertriebs GmbH

Zur Porta 9
D-32457 Porta Westfalica

Electrical installation

Electrical installation work must only be performed 
by a qualified electrician. This work must be 
carried out in accordance with the regulations 
according to IEC 60364-7-701 (corresponding 
to VDE 0100 Part 701) as well as all national and 
local regulations.

Installation

Refer to the dimensional drawings on fold-out page I.

Install fitting, 

see fold-out page II, Figs. [1] and [2].

Important:

 The cable must not be pinched.

Flush pipes thoroughly before and after installation 

(observe EN 806)

!

Install control unit,

 see Figs. [3] and [4].

Important:

 Do not connect voltage supply yet.

Connect fitting,

 see Figs. [2], [5] to [7].

Open hot and cold water supply and check that 
connections are watertight.

Connect voltage supply via mains plug,

 see Fig. [8].

The display illuminates and the remaining filter capacity is 
displayed in percent.

This product conforms to the requirements of the 
relevant EU guidelines.

www.divapor.com

Содержание Blue Pure 31087

Страница 1: ... 34 TR 49 EST 64 UA 79 F 7 DK 22 GR 37 SK 52 LV 67 RUS 82 E 10 N 25 CZ 40 SLO 55 LT 70 I 13 FIN 28 H 43 HR 58 RO 73 Design Engineering GROHE Germany GROHE Blue Pure GROHE Blue Pure 99 0202 031 ÄM 229785 01 14 31 087 31 338 w w w d i v a p o r c o m ...

Страница 2: ...I Please pass these instructions on to the end user of the fitting 31 338 31 087 w w w d i v a p o r c o m ...

Страница 3: ...II 1 max 60mm max 45mm 19 017 19 017 13mm 13mm 2 3 4 9 1 2 10 11 30mm 3mm 8 5 19mm 6 19mm 19mm 19mm 7 12 17mm w w w d i v a p o r c o m ...

Страница 4: ...ajor pressure differences between hot and cold water supply Flow rate at 0 3 MPa flow pressure Fitting tap water approx 9 l min Filter cartridge GROHE Blue water approx 3 5 l min Ambient temperature 4 32 C Temperature Hot water inlet max 70 C Recommended energy saving 60 C Adjustable bypass factory setting 2 Filter capacity at bypass setting 2 Carbonate hardness 10 24 KH max 750 liters corresponds...

Страница 5: ...lay Press the c button and select the required value C4 carbonate hardness 9 bypass 3 Factory setting C3 carbonate hardness 10 24 bypass 2 C2 carbonate hardness 25 29 bypass1 C1 carbonate hardness 30 bypass 0 Press and hold the c button until the setted value stops flashing Release the c button The remaining filter capacity is displayed The liter capacity of the cartridge varies according to the w...

Страница 6: ...g Care Instructions Environment and recycling Used filter cartridges can be disposed of hazard free in domestic waste Fault Cause Remedy Water not flowing Water supply interrupted Open shut off valves Filtered water not flowing Water supply interrupted Establish water supply to fitting No filtered water E3 in the display No connection between fitting and cooler carbonator Cable or connector faulty...

Страница 7: ...0 l 10 24 KH 17 43 fH 3 39 8 75 mval l 1 7 4 37 mmol l 2 C3 750 l 1 800 l 3 000 l 25 29 KH 44 52 fH 8 76 10 35 mval 4 38 5 22 mmol l 1 C2 350 l 1 000 l 1 500 l 30 KH 53 fH 10 36 mval l 5 33 mmol l 0 C1 250 l 650 l 1 000 l A B 40 691 40 547 9 dGH 3 C3 700 l 3 000 26 35 dGH 2 C2 200 l 3 000 36 dGH 1 C1 90 l 3 000 w w w d i v a p o r c o m ...

Страница 8: ...w w w d i v a p o r c o m ...

Страница 9: ... co jp KZ 7 727 311 07 39 info cac grohe com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL 1 800 80 6570 info singapore grohe com N 47 22 072070 grohe grohe no NL 31 79 3680133 vragen nl grohe com NZ 09 373 4324 P 351 234 529620 commercial pt grohe com PL 48 22 5432640 bLuro grohe com pl RI 62 21 2358 4751 info singapore grohe com RO 40 21 2125050 info ro grohe com ROK 82 2 559 0...

Отзывы: