2.3.1
Control unit
The electronic control unit steers and controls the course of the greasing cycles. All system- and
program-parameters are stored in it. The control unit processes malfunction reports, gives possible
alarm reports and automatically records a log. All relevant incidents will be stored in the log.
All data in the control unit will always be retained, even when the power or system is switched OFF.
To view the log an Uni- or PC-GINA is needed.
The control unit is electrically connected according to the wiring diagram shown (see Figure 2.3).
The positive pole of the supply voltage (+15) is connected to pin-1.
As soon as the ignition is switched ON, the program cycle is started at the point where it was
interrupted during the preceding cycle.
If the preceding cycle was interrupted during the pumping phase by switching OFF ignition, this
pumping phase will be continued the moment ignition is switched ON again.
Figure 2.3
Wiring diagram with signal lamp
PUMP
L
T
BK
RD
OR
BU
G
Y
PU
P
I
+
-
M
1
+
1
5
3
7
PS
8
6
K
5
PS
4 +SL
2
G
ND
VAL
1
PUMP
POWER
J5
VAL2
LOW
TEST
J
8
3 4
1
2
3
4
5
6
7
8
9
1
0
11
22K
12V 20A
24V 10A
1. Electric motor of pump
2. 5/2-way valve
3. Minimum level switch
4. Test push-button
5. Control unit
6. Pump housing
7. Battery
8. Ignition switch
9. Pressure switch
10. Greasing cycle selector switch
11. Signal lamp