Automatic Greasing System
Twin-3
Maintenance
35
Da
te
of
is
sue
:
Ja
nu
ar
y 2
0
1
1
EG1703P03
4.
+
Successive no pressure
in line-B
The pressure switch did not close
during a greasing cycle in primary
line-B.
Possibly caused by:
a. Broken/damaged primary line-B.
a. Check condition of primary lines
and its connectors. Replace or
repair when necessary.
b. Metering unit causes internal by
pass.
b. Proceed with “Procedure when
an internal system leak is sus-
pected” on page 43.
c. Air trapped into pump and or
primary line-B.
c1. Refill reservoir until reservoir is
bled. See paragraph 4.5.2 “Filling
the reservoir”.
c2. Bleed the pump and primary
lines. Proceed with paragraph 4.3
& 4.4 “Bleeding pump & system”.
5.
+
Successive pressure
before cycle in line-A
The pressure switch was still closed
at the outset of a cycle in primary
line-A.
Possibly caused by:
a. Damaged PS wiring harness to
where wires are joined.
a. Check wiring and connectors.
Replace or repair when
necessary.
b. 5/2-way valve did not operate
correctly.
b. Check 5/2-way valve and operate
manually with the use of an Uni-
or PC-GINA. Replace or repair
when necessary.
c. Pressure switch failed/broken.
c. Check and or replace pressure
switch (valve).
6.
+
Successive pressure
before cycle in line-B
The pressure switch was still closed
at the outset of a cycle in primary
line-B.
Possibly caused by:
a. Interrupted PS wiring harness to
where wires are joined.
a. Check wiring and connectors.
Replace or repair when
necessary.
b. 5/2-way valve did not operate
correctly.
b. Check 5/2-way valve and operate
manually with the use of an Uni-
or PC-GINA.
Replace or repair when
necessary.
c. Pressure switch failed/broken.
c. Check and or replace pressure
switch (valve).
Error code / malfunction
Cause
Solution
Содержание EG1703P03
Страница 4: ...Table of Contents 4 EG1703P03 Automatic Greasing System Twin 3 Date of issue January 2011 ...
Страница 47: ......