OM-TDH/C

6

Correct water level

WARNING

THE KETTLE MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND
PLUMBING.  IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE
EQUIPMENT.

Installation and Initial Start-Up

A. Installation

The TDH/C kettle should be installed in a ventilated

system during any pressure testing of the gas

room for efficient performance.  Items which might
obstruct or restrict the flow of air for combustion and
ventilation must be removed.  The area directly around
the appliance must be cleared of any combustible
material.

1.

Installation on combustible floors is allowed.  The
unit requires a minimum clearance to combustible
and noncombustible construction of six inches at the
rear and six inches at the sides.  

2.

Groen recommends installation of the unit under a
vent hood.  The base must be fastened to the
working surface.

3.

Complete the piping to the gas service main using
½ inch IPS pipe or an approved equivalent.  

WARNING

THIS UNIT IS FOR COMMERCIAL USE.  DO NOT
USE HOME OR RESIDENTIAL GRADE GAS
CONNECTIONS. THEY DO NOT MEET GAS CODES
AND COULD BE HAZARDOUS.

4.

Provide 115 VAC, 60 cycle, 1 phase, 1 AMP electric
service. Local codes and/or The National Electrical
Code should be observed in accordance with
ANSI/NFPA-70 latest edition.  AN ELECTRICAL
GROUND IS REQUIRED.  The electrical schematic
is located on the inside of the service panel, and at
the rear of this manual.  In Canada provide electric
service in accordance with the 

Canadian Electrical

Code

, C.S.A.-C22.1 Part 1 and/or local codes.

5.

The installation must conform with local codes or
the American National Standards Z223.1 - latest
edition National Fuel Gas Code. The kettle should
be installed in an adequately ventilated room with
provision for adequate air supply. the best
ventilation will employ a vent hood and exhaust fan
with no direct connection between the vent duct and
the kettle flue. DO NOT obstruct the flue or vent
duct after installation.   In Canada, the installation
must conform to CAN/CGA B149 

Installation Codes

for Gas Burning Appliances and Equipment

 and/or

local codes.

6.

The appliance and its individual shutoff valve must
be 

disconnected

 from the gas supply piping

supply system at test pressures that 

exceed

 ½

PSIG (3.45 kPa).  The kettle must be 

isolated

from the gas supply piping system by closing its
individual manual shutoff valve during any
pressure testing of that system at test pressures

which equal or are less than 

½ PSIG (3.45

kPa).  

7.

Adequate space for proper servicing and
operation is required. DO NOT block any air
intake spacings to the combustion chamber or
obstruct air flow.  

8.

After the kettle has been connected to the gas
supply, check all gas joints for leaks. A thick
soap solution or other suitable leak detector
should be used. 

Do not use flame when

checking the leaks.

9.

Once the unit is anchored to a mounting
surface, Apply a small bead of silicone caulk
around the perimeter of the kettle base.

10. Make sure the water level is correct in the

jacket, by confirming that the level is near the
middle of the sight glass. If the water level is
low, follow the instructions in 

Jacket Filling and

Содержание TDHC Series

Страница 1: ...DIAGRAM FOR First Choice Group Blakeney Way Kingswood Lakeside Cannock Staffs WS11 8LD TEL 01543 577778 FAX 01543504141 Email enquires firstchoice cs co uk Web www firstchoice cs co uk Steam Jacketed...

Страница 2: ...T LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND...

Страница 3: ...R HOSE DOWN THE CONTROL CONSOLE ELECTRICAL CONNECTIONS ETC CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING TAKE PRECAUTIONS WEAR RUBBER GLOVES GOGGLES OR FACE SHIELD A...

Страница 4: ...OR WARNINGS 2 EQUIPMENT DESCRIPTION 4 INSPECTION UNPACKING 5 INSTALLATION INITIAL START UP 6 OPERATION 8 CLEANING 11 MAINTENANCE 12 SEQUENCE OF OPERATION 14 TROUBLESHOOTING 14 PARTS LISTS 16 SCHEMATIC...

Страница 5: ...with electronic ignition Charged at the factory with chemically pure water containing rust inhibitors the steam source provides kettle temperatures of 150 F to approximately 295 F o The gas supply sh...

Страница 6: ...lls shipping damage or shipment errors to the delivery When installation is to begin cut the straps holding the agent kettle on the skid and lift the kettle straight up off the CAUTION SHIPPING STRAPS...

Страница 7: ...nce with the Canadian Electrical Code C S A C22 1 Part 1 and or local codes 5 The installation must conform with local codes or the American National Standards Z223 1 latest edition National Fuel Gas...

Страница 8: ...SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL After the kettle has been installed the installer should test to ensure that it is operating correctly 1 Remove literature and packing materials from insid...

Страница 9: ...ions WARNING KEEP AREA AROUND KETTLE FREE AND CLEAR OF ALL COMBUSTIBLE MATERIALS DO NOT ATTEMPT TO LIGHT ANY BURNER WITH A FLAME CAUTION HEATING AN EMPTY KETTLE MAY CAUSE THE RELEASE OF STEAM FROM THE...

Страница 10: ...THE KETTLE RIM TO ALLOW CLEARANCE FOR STIRRING BOILING PRODUCT AND SAFE TRANSFER WARNING WHEN TILTING KETTLE 1 WEAR PROTECTIVE OVEN MITT AND PROTECTIVE APRON 2 USE DEEP CONTAINER TO CONTAIN AND MINIM...

Страница 11: ...pasta shapes b Tips For Use 1 Allow for the water displacement of the basket and product to be cooked This may mean only filling the kettle half full of water Test the basket and product displacement...

Страница 12: ...ucted by the supplier Clean the unit thoroughly A cloth moistened with cleaning solution can be used to clean controls housing electrical conduit etc d Rinse the kettle thoroughly with hot water Then...

Страница 13: ...provided at the rear of this manual valve lever for about one second Repeat Each time service is performed on this Groen this step then let the valve lever snap equipment enter the date on which the w...

Страница 14: ...ve open while you pour to let air escape from the jacket Continue adding water until the water level rises to the center of the round sight glass c Close the gate valve d Air that gets into the jacket...

Страница 15: ...off cycling continues and Troubleshooting Your Groen kettle is designed to operate smoothly and efficiently if properly maintained However the following is a list of checks to make in the event of a p...

Страница 16: ...lowing 1 Check the pilot gas line for kinks and obstructions Y 2 Clean orifice if necessary Y 3 Replace the pilot valve Y d That the pilot spark gap is 7 64 inch and located in the pilot gas stream If...

Страница 17: ...OM TDH C 16 Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable voltage and phase...

Страница 18: ...plate TDH 026450 58 Screw 1 4 20 x 3 4 hex ss TDH 40 005609 Cladding Panel TDH C 20 124758 35 Electrode Water Level 074623 Screw 1 4 20 x 1 1 2 hex ss TDH 20 005469 10 Spacer pedestal 128035 36 Switch...

Страница 19: ...5 8 7 8 4 3 12 14 17 13 15 16 OM TDH C 18 Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable...

Страница 20: ...use Holder Type 3 AG 077854 11 Insert 8 screw nylon 124759 3 Control Water Level 115 V 097023 12 P C Board Mounting Post 099901 4 Transformer 50 VA 120 208 240 074839 13 Micro Switch 002982 5 Terminal...

Страница 21: ...OM TDH C 20 Schematic...

Страница 22: ...Serial No __________________________________ Location ____________________________________ Date Purchased _____________________________ Date Installed _______________________________ Purchase Order N...

Страница 23: ...60 Battery March Park Quincy Massachusetts 02269 NFPA 54 Installation of Gas Appliances Gas Piping NFPA 70 The National Electrical Code NATIONAL SANITATION FOUNDATION 3475 Plymouth Rd Ann Arbor Michig...

Страница 24: ...al transportation costs time mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boiler maintenance c...

Страница 25: ...1055 Mendell Davis Drive OM TDH C Revised 4 99 Jackson MS 39272 Part Number 121049 Phone 601 372 3903 Fax 601 373 9587...

Отзывы: