Groen TDHC Series Скачать руководство пользователя страница 10

OM-TDH/C

9

2.

To Stop Kettle Heating

 

a.

Turn the thermostat dial to OFF.

b.

Turn the toggle switch OFF.

c.

For a prolonged shut-down:

1.

Follow the procedure above.

2.

Turn the manual gas valve OFF (handle at
right angle to gas line).

3.

Disconnect the unit’s electrical power.

3.

To Relight Kettle

a

Close main gas supply valve.

b.

Set on-off switch to OFF.

c.

Set thermostat to OFF.

d.

Wait five minutes, then proceed as directed
under 

To Start Kettle

.

4.  If Electric Power Fails,

 

do not attempt to operate

the unit. When power is restored, proceed as
directed in 

To Start Kettle

.

5.

To Transfer Product or Empty Kettle

:

The kettle body is tilted using the crank tilt handwheel.
Turning the crank clockwise tilts the kettle body;
counter-clockwise returns it to an upright position. The
kettle body will remain in any tilted position.

WARNING

AVOID ALL DIRECT CONTACT WITH HOT FOOD OR
WATER IN THE KETTLE. DIRECT CONTACT COULD
RESULT IN SEVERE BURNS.  

TAKE CARE TO AVOID CONTACT WITH HOT
KETTLE BODY OR HOT PRODUCT, WHEN ADDING
INGREDIENTS, STIRRING OR TRANSFERRING
PRODUCT TO ANOTHER CONTAINER.

CAUTION

DO NOT OVERFILL THE KETTLE WHEN
COOKING, HOLDING OR CLEANING. KEEP
LIQUIDS 2-3” (5-8 cm) BELOW THE KETTLE
RIM TO ALLOW CLEARANCE FOR STIRRING,
BOILING PRODUCT AND SAFE TRANSFER.

WARNING

 

WHEN TILTING KETTLE:
1) WEAR PROTECTIVE OVEN MITT AND

PROTECTIVE APRON.

2)  USE DEEP CONTAINER TO CONTAIN AND

MINIMIZE PRODUCT SPLASHING.

3) PLACE CONTAINER ON STABLE, FLAT

SURFACE, CLOSE TO THE KETTLE.

4) STAND TO AWAY FROM POUR PATH OF

HOT CONTENTS.

5)  POUR SLOWLY, KEEP CONTROL OF

KETTLE, AND RETURN KETTLE BODY
SLOWLY TO UPRIGHT POSITION AFTER
CONTAINER IS FILLED OR TRANSFER IS
COMPLETE.

6)  DO NOT OVERFILL CONTAINER. AVOID

DIRECT SKIN CONTACT WITH HOT
CONTAINER AND ITS CONTENTS.

6. Use of Common Accessories

1.

Lift-Off Cover

a.

As with stock pot cooking, an optional lift
off cover will speed up the heating of water
and food products. A cover helps retain
heat in the cooking vessel and reduces the
amount of heat and humidity released into
the kitchen. Use of a cover can reduce
some product cook times and help maintain
the temperature, color and texture of
products being held or simmered for
extended periods. 

b.

Make sure the plastic ball handle is secure
on the lift off cover before using. ALWAYS
use the plastic handle to place or remove
cover from the kettle. Wear protective oven
mitts and a protective apron.

c.

When putting the cover on the kettle,
position it on top of kettle rim, with its flat
edge facing the pouring lip.

d.

When removing cover:

1) Firmly grasp plastic handle

Содержание TDHC Series

Страница 1: ...DIAGRAM FOR First Choice Group Blakeney Way Kingswood Lakeside Cannock Staffs WS11 8LD TEL 01543 577778 FAX 01543504141 Email enquires firstchoice cs co uk Web www firstchoice cs co uk Steam Jacketed...

Страница 2: ...T LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND...

Страница 3: ...R HOSE DOWN THE CONTROL CONSOLE ELECTRICAL CONNECTIONS ETC CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING TAKE PRECAUTIONS WEAR RUBBER GLOVES GOGGLES OR FACE SHIELD A...

Страница 4: ...OR WARNINGS 2 EQUIPMENT DESCRIPTION 4 INSPECTION UNPACKING 5 INSTALLATION INITIAL START UP 6 OPERATION 8 CLEANING 11 MAINTENANCE 12 SEQUENCE OF OPERATION 14 TROUBLESHOOTING 14 PARTS LISTS 16 SCHEMATIC...

Страница 5: ...with electronic ignition Charged at the factory with chemically pure water containing rust inhibitors the steam source provides kettle temperatures of 150 F to approximately 295 F o The gas supply sh...

Страница 6: ...lls shipping damage or shipment errors to the delivery When installation is to begin cut the straps holding the agent kettle on the skid and lift the kettle straight up off the CAUTION SHIPPING STRAPS...

Страница 7: ...nce with the Canadian Electrical Code C S A C22 1 Part 1 and or local codes 5 The installation must conform with local codes or the American National Standards Z223 1 latest edition National Fuel Gas...

Страница 8: ...SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL After the kettle has been installed the installer should test to ensure that it is operating correctly 1 Remove literature and packing materials from insid...

Страница 9: ...ions WARNING KEEP AREA AROUND KETTLE FREE AND CLEAR OF ALL COMBUSTIBLE MATERIALS DO NOT ATTEMPT TO LIGHT ANY BURNER WITH A FLAME CAUTION HEATING AN EMPTY KETTLE MAY CAUSE THE RELEASE OF STEAM FROM THE...

Страница 10: ...THE KETTLE RIM TO ALLOW CLEARANCE FOR STIRRING BOILING PRODUCT AND SAFE TRANSFER WARNING WHEN TILTING KETTLE 1 WEAR PROTECTIVE OVEN MITT AND PROTECTIVE APRON 2 USE DEEP CONTAINER TO CONTAIN AND MINIM...

Страница 11: ...pasta shapes b Tips For Use 1 Allow for the water displacement of the basket and product to be cooked This may mean only filling the kettle half full of water Test the basket and product displacement...

Страница 12: ...ucted by the supplier Clean the unit thoroughly A cloth moistened with cleaning solution can be used to clean controls housing electrical conduit etc d Rinse the kettle thoroughly with hot water Then...

Страница 13: ...provided at the rear of this manual valve lever for about one second Repeat Each time service is performed on this Groen this step then let the valve lever snap equipment enter the date on which the w...

Страница 14: ...ve open while you pour to let air escape from the jacket Continue adding water until the water level rises to the center of the round sight glass c Close the gate valve d Air that gets into the jacket...

Страница 15: ...off cycling continues and Troubleshooting Your Groen kettle is designed to operate smoothly and efficiently if properly maintained However the following is a list of checks to make in the event of a p...

Страница 16: ...lowing 1 Check the pilot gas line for kinks and obstructions Y 2 Clean orifice if necessary Y 3 Replace the pilot valve Y d That the pilot spark gap is 7 64 inch and located in the pilot gas stream If...

Страница 17: ...OM TDH C 16 Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable voltage and phase...

Страница 18: ...plate TDH 026450 58 Screw 1 4 20 x 3 4 hex ss TDH 40 005609 Cladding Panel TDH C 20 124758 35 Electrode Water Level 074623 Screw 1 4 20 x 1 1 2 hex ss TDH 20 005469 10 Spacer pedestal 128035 36 Switch...

Страница 19: ...5 8 7 8 4 3 12 14 17 13 15 16 OM TDH C 18 Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable...

Страница 20: ...use Holder Type 3 AG 077854 11 Insert 8 screw nylon 124759 3 Control Water Level 115 V 097023 12 P C Board Mounting Post 099901 4 Transformer 50 VA 120 208 240 074839 13 Micro Switch 002982 5 Terminal...

Страница 21: ...OM TDH C 20 Schematic...

Страница 22: ...Serial No __________________________________ Location ____________________________________ Date Purchased _____________________________ Date Installed _______________________________ Purchase Order N...

Страница 23: ...60 Battery March Park Quincy Massachusetts 02269 NFPA 54 Installation of Gas Appliances Gas Piping NFPA 70 The National Electrical Code NATIONAL SANITATION FOUNDATION 3475 Plymouth Rd Ann Arbor Michig...

Страница 24: ...al transportation costs time mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boiler maintenance c...

Страница 25: ...1055 Mendell Davis Drive OM TDH C Revised 4 99 Jackson MS 39272 Part Number 121049 Phone 601 372 3903 Fax 601 373 9587...

Отзывы: