6. Branch Circuit Protection
Each conductor must have over-current protection. Refer to the label on the back
of the unit for the proper wire type and size. Connections to the unit must be
watertight. We strongly recommend that the HY-6E Steamer have its own branch
circuit protection. Current and power demands for the different units are as follows:
WATER CONNECTION(S)
Install a check valve to prevent back flow in the incoming cold water line, as required by
local plumbing codes. Water pressure in the line should be between 30 and 60 PSIG and
must deliver a flow rate of 1.5 to 3.0 gallons per minute. If pressure is above 60 PSIG, a
pressure regulator will be needed.
A ¾ inch female NH connector (garden hose type) is used to attach the water supply to
the inlet valve. Minimum inside diameter of the water feed line is ½ inch. Use a washer
in the hose connection. Do not allow the connection to leak, no matter how slowly. If
you have the dual water connection option, put the treated water (softened) to the right
intake (looking from the rear of the unit), and untreated water to the left. Connections for
both are made as described above.
DRAIN CONNECTION
The HY-6E Steamer must be leveled front to back. A 1½ inch (38mm) ID hose may be
attached to the drain pipe by means of a hose.
Do NOT use plastic pipe. The drain must withstand boiling water.
Install the drain line with a constant downward pitch. Do not allow any water traps in
the line. A trap can cause pressure to build up inside the cavity during steaming, which
will make the door gasket leak. IMPROPER CONNECTION OF THE DRAIN WILL VOID YOUR
WARRANTY
Installation & Start-Up
WARNING
DO NOT CONNECT THE DRAIN DIRECTLY TO A
BUILDING DRAIN. BLOCKING THE DRAIN IS
HAZARDOUS.
CAUTION
DO NOT USE PLASTIC PIPE. DRAIN MUST BE
RATED FOR VERY HOT WATER.
Don’t allow water traps in the hose.