12 OM-HY/6E
Cleaning
DELIMING STEPS (Use Touch Pad)
STEP 1
Press ON/OFF to turn steamer off. Open door.
STEP 2
Let cavity cool for 5 minutes or longer. While cool, wipe out cavity. Close door.
STEP 3
Press and hold CLEAN while also turning steamer on by pressing ON/OFF, until only
DELIME and POWER lights remain on (all lights will turn on, then off, except DELIME
and POWER).
STEP 4
After 5 minutes, beeper will beep rapidly, signaling you to add Groen Delimer/ Des-
caler. Door(s) must remain closed for entire delime cycle.
STEP 5
Pour 1 pint (2 cups) of delimer PER CAVITY into upper and /or lower deliming port(s)
and then close port(s). Press CLEAN. Double-stacked unit cavities may be delimed
together or seperately
STEP 6
Delime cycle will start, taking about 30 minutes. When delime cycle is complete, DE-
LIME light will appear, DONE light will flash and beeper will beep.
STEP 7
Press ON/OFF to turn steamer off. Let cavity cool for 5 minutes or longer. Open door,
wipe out inside of cavity and wipe door gasket. Close door.
STEP 8
To use steamer, press ON/OFF. When READY light appears, steamer is ready to use.
NOTES
:
•
If DELIME light flashes rapidly (5 times per second), press DELIME to restart
delime cycle.
•
If power outage occurs during deliming, delime cycle must be restarted. Press
DELIME.
•
For best performance, do not interrupt delime cycle. If delime cycle must be
stopped, press ON/OFF to turn on. Set timer for 5 minutes. After beeper beeps,
press ON/OFF to turn off. Let cavity cool for 5 minutes or longer, carefully open
door(s) and wipe out cavity completely.
CAUTION
NEVER LEAVE A CHLORINE SANITIZER IN
CONTACT WITH STAINLESS STEEL
SURFACES FOR LONGER THAN 30
MINUTES. LONGER CONTACT CAN
CAUSE CORROSION.
Once the cavity has cooled, reach in and
remove the fan baffle partition by lifting it
upward and drawing it toward the center of
the cavity.
Pour two cups of Groen de-liming solution into
the de-liming port.
Содержание HYPERSTEAM HY-6E