Groen (2)CC10-GF Скачать руководство пользователя страница 25

OM-CC-G

25

NOTE

: For double stacked ovens, wait five minutes

after starting the first oven before you refill
the fill tank with de-limer for the second
oven.  The first oven should read “CL:40" or
less before you add delimer for the second
oven (See step 5, below).

e.

Step 5

 — Cooking Chamber and/or De-

liming

Close the oven door and press START.  The
display will now read “CL:45," and the colon
[:] will blink once each second.  The unit will
begin an automatic sequence that involves
heating, draining and refilling the steam
generator at various time intervals.  This
Clean Cycle takes in 45 minutes.  The
display will count down each minute.

NOTE: To exit the Clean Cycle at any time press

and hold the CLEAR touch pad for three
seconds.

After halting the Clean Cycle, and before you
cook any food in the unit, be sure to wash
out all chemical residue thoroughly, by filling
and draining the steam generator.  (Enter the
Steam Mode and wait 60 to 90 seconds to
fill; enter the Oven Mode, take the unit out of
all modes or simply turn it off to drain).  Wait
at least three minutes before restarting the
unit.

Also wipe chemical residues from the
cooking chamber with a wet, clean cloth
before you cook.  

Rinse the cloth often

This cleaning must include both sides of the
four removable partitions, the racks, and the
tubes and walls behind the partitions.  The
racks and partitions may be rinsed in a sink.

f.

Step 6

 — Cooking Chamber and/or De-

liming

When the Clean Cycle is complete, the
display will read “00:00.”

WARNING

UNIT MAY BE HOT ENOUGH TO BURN YOU.
DO NOT TOUCH HOT SURFACES.

g.

Step 7

 — Cooking Chamber and/or De-

liming

Before you use the unit for cooking, wipe the
entire interior with a clean, wet cloth.  

Rinse

the cloth often

.  This cleaning must include

both sides of the four removable partitions,
the racks, and the tubes and walls behind the
partitions.  The racks and partitions may be
rinsed in a sink.

WARNING

DO NOT OPERAT E THE UNIT IN ANY MODE
UNLESS ALL FOUR REMOVABLE PARTITIONS
HAVE BEEN RETURNED TO T HEIR PROPER
LOCATIONS.

i.

Step 8

 —Cooking Chamber and/or De-

liming

If the unit will not be used right away, leave
the door open long enough to allow the
chamber to dry completely.

E.

Errors During Cleaning

If the timer stops and the SERVICE light stays
on, there has been an error which prevents the
unit from completing the clean cycle.  Take the
following steps:

1)

Reset the unit.  Reenter “99."  The display
should read “CC” or “CL.”  Press START.

2)

If the unit fails again to complete its clean
cycle, call your authorized Groen Service
Agency.

F.

Clean Cycle Counter

The unit tracks the total number of clean cycles
completed.  To check this total, first turn off the
unit.  Press and hold the 0 touch pad while
turning on the unit.  The total will be displayed in
the timer window.  This counter cannot be reset.

Содержание (2)CC10-GF

Страница 1: ...S IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS S...

Страница 2: ...DE OF THE STEAMER DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING ALLOW COOKING...

Страница 3: ...UIPMENT DESCRIPTION 4 INSPECTION AND UNPACKING 5 WATER CONDITIONING REQUIREMENTS 6 INSTALLATION 7 INITIAL START UP 11 OPERATING INSTRUCTIONS 13 CLEANING 19 MAINTENANCE 26 TROUBLESHOOTING 26 DIAGRAMS A...

Страница 4: ...the unit and touch pads to select the mode of operation and to switch on power A digital readout shows the selected temperature which is entered by turning a dial Pilot burner status is shown by a lig...

Страница 5: ...m the skid Pull the carton up off the unit Be careful to avoid personal injury or equipment damage from nails and sharp pieces of wood or staples which might be left in carton walls Write down the mod...

Страница 6: ...le water 30 40 ppm TDS 2 If your water contains scale forming minerals as most water does use a well maintained water softener Whether an exchangeable softener cartridge or a regenerating system is ch...

Страница 7: ...al manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than PSI 3 45 kPa 2 Gas Supply Connections WARNING THIS UNIT IS FOR COMMERCIAL U...

Страница 8: ...Connection a Unit Without Drain Tank A 1 inch 4 cm ID CC10 G or 2 inch 5 cm ID hose CC20 G may be attached to the supplied drain outlet with a clamp Do not use plastic pipe because the drain must with...

Страница 9: ...OM CC G 9 Convection Combo Utility Connections NOTE Remove right side panel to make connections at terminal block in rear of control compartment...

Страница 10: ...OM CC G 10 Proper Drain Line Connections...

Страница 11: ...or ignition During initial start up the pilot may require several trials in order to bleed air from the gas piping Subsequent start up should only require about five seconds to achieve ignition NOTE S...

Страница 12: ...8 To Test Combo Mode Operation turn on the p o w e r a nd clear any time from the timer display Press the COMBO touch pad Set the COOK temperature to 350o F 175o C The WAIT light will come on It will...

Страница 13: ...ime values c CLEAR Pressing this touch pad once stops the beeper and resets the timer to the time that was last set Pressing twice clears it to 00 00 At the end of a cooking period opening the door is...

Страница 14: ...OM CC G 14 Operation Standard Operating Controls...

Страница 15: ...NOTE You cannot change operating modes while the timer is running c The unit will be in the mode of operation in which it was last used Because of this the indicator light for that mode will be lit If...

Страница 16: ...me to zero by either 1 opening the door and pressing CLEAR or pressing CLEAR twice A new cooking time may then be set by using the number keys 2 Oven Mode a To use the Convection Combo as a convection...

Страница 17: ...hen you turn on the power see the Troubleshooting section If the door is closed and the cooking temperature is above 200o F 93o C the fan will begin to operate b If the power is already on and there i...

Страница 18: ...o stop cooking take the pans out of the oven using hot pads or oven mitts to protect your hands from the hot pans The unit will continue steaming and heating the oven at the set temperature until the...

Страница 19: ...r C Single CC10 G Units NOTE For instructions about cleaning the interior of double stacked CC10 G units or any CC20 G units go directly to Section D below PRECAUTIONS WARNING DISCONNECT THE POWER SUP...

Страница 20: ...de limer solution Remember if the HOT light is on use the Fast Cool method to reduce the temperature The timer display will show CC or CL c Step 3 Cooking Chamber WARNING BEFORE REACHING INTO THE OVE...

Страница 21: ...d to engage the four hooks to their support posts If absolutely necessary you may remove the wire rack support Left The left partition includes a back plate and an air distribution baffle Push down to...

Страница 22: ...r halting the Clean Cycle and before you cook any food be sure to thoroughly wash out all chemical residue by filling and draining the steam generator Enter Steam Mode and wait 60 to 90 seconds to fil...

Страница 23: ...mer and press the mode s touch pad Remove the cap from the fill port located on the front of the stand directly below the control panel Add de liming solution to the fill tank When using Lime A Way or...

Страница 24: ...tion has a small circular pattern of drain holes Place it directly down onto the four support posts Right The right partition includes a large circular flared opening that must be centered in front of...

Страница 25: ...e tubes and walls behind the partitions The racks and partitions may be rinsed in a sink f Step 6 Cooking Chamber and or De liming When the Clean Cycle is complete the display will read 00 00 WARNING...

Страница 26: ...lid State Controls If problems persist call an authorized Groen Service Agency If the controls stop responding to normal commands or the unit is behaving oddly reset the controls using the following p...

Страница 27: ...ice Agency 7 Out of Calibration Units Before 3 97 Only The unit will operate in all modes Call your Groen Service Agency 7A Time Between Fills Units After 3 97 Only Check for a leaky fill valve The un...

Страница 28: ...OM CC G 28 Diagrams Schematics...

Страница 29: ...3 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA 70 The National Electrical Code NATIONAL SANITATION FOUNDATION 3475 Plymouth Road Ann Arbor...

Страница 30: ...OM CC G 30 Service Log Model No Serial No Date Purchased Purchase Order No Purchased From Location Date Installed For Service Call Date Maintenance Performed Performed by...

Страница 31: ...tal to portal transportation costs time and mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boile...

Страница 32: ...1055 Mendell Davis Drive Jackson MS 39212 Telephone 601 372 3903 Fax 601 373 9587 OM CC G Revised 7 00 Part Number 121020 Rev A...

Отзывы: