OM-CC-G
19
Cleaning
To keep your Convection Combo™ in proper operating condition and to make the cleaning process easier, cleaning
should be a daily activity.
A.
Suggested Tools and Cleaners
1.
Mild detergent
2.
Stainless steel exterior cleaner such as
Zepper®
3.
Steam generator de-liming agent, such
as
Groen Delimer Descaler,
(P/N
114800) Lime-A-Way® or an equivalent.
A liquid de-liming agent will be easier to use
than crystals or powders.
See the warning
about chlorides below
.
4.
De-greaser, such as EncompasS®,
Groen Degreaser
, Malone 34®, Puritan
Puribrute®, or Con-Lie®
5.
Cloth or sponge
6.
Plastic wool or a brush with soft bristles
7.
Spray bottle
8.
Measuring cup
9.
Nylon pad
10. Towels
11. Plastic disposable gloves
B. Procedure
1.
Exterior Cleaning
a.
Prepare a warm solution of the mild
detergent as instructed by the supplier.
Wet a cloth with this solution and wring it out.
Use the moist cloth to clean the outside of
the unit. Do not allow freely running liquid to
touch the controls, the control panel, any
electrical part, or any open louver.
b.
To remove material which may be stuck to
the unit, use plastic wool, a fiber brush, or a
plastic or rubber scraper with a detergent
solution.
c.
Stainless steel surfaces may be polished
with a recognized stainless steel cleaner
such as Zepper®.
C. Single CC10-G Units
NOTE:
For instructions about cleaning the interior of
double-stacked CC10-G units or any CC20-G units,
go directly to Section D, below.
PRECAUTIONS
WARNING
DISCONNECT T HE POWER SUPPLY
BEFORE CLEANING THE OUTSIDE OF
THE UNIT.
K E E P W A T E R A N D C L E A N I N G
SOLUTIONS OUT OF CONTROLS AND
ELECT RICAL COMPONENT S. NEVER
HOSE OR ST EAM CLEAN ANY PART OF
THE UNIT.
BE CAREFUL CLEANING THE TOP FLUE
COVER AND THE OVEN TOP. BOTH
AREAS MAY BE VERY HOT.
DON’T MIX DE-LIMING AGENTS (ACID)
W I T H D E - G R E A S E R S ( A L K A L I )
ANYWHERE IN THE UNIT
AVOID CONTACT WITH ANY CLEANERS,
DE-LIMING AGENT OR DE-GREASER AS
RECOM M ENDED BY THE SUPPLIER.
M ANY ARE HARMFUL. READ T HE
W A R N I N G S A N D F O L L O W T H E
DIRECTIONS!
EVEN WHEN THE UNIT HAS BEEN SHUT
OFF, DON’T PUT HANDS OR TOOLS INTO
THE COOKING CHAMBER UNTIL THE FAN
HAS STOPPED TURNING.
DON’T USE ANY CLEANING OR DE-
LIMING AGENT THAT CONTAINS ANY
SULFAMIC AGENT OR ANY CHLORIDE,
INCLUDING HYDROCHLORIC ACID (HCl).
TO CHECK FOR CHLORIDE CONTENT
SEE ANY MATERIAL SAFET Y DATA
SHEETS PROVIDED BY THE CLEANING
AGENT MANUFACTURER
.
UNIT MAY BE HOT . T AKE PRECAUTIONS
TO PREVENT CONT ACT WITH HOT
SURFACES.
To clean the cooking chamber and/or de-lime the steam
generator of the CC10-G, a special sequence of
operations (the Clean Cycle) has been programmed into
the Convection Combo™ computer. To run this
automatic Clean Cycle for cleaning, de-liming or both
actions at the same time, follow the instructions outlined
in the following table.
Содержание (2)CC10-GF
Страница 10: ...OM CC G 10 Proper Drain Line Connections...
Страница 14: ...OM CC G 14 Operation Standard Operating Controls...
Страница 28: ...OM CC G 28 Diagrams Schematics...