Power Input
The
GRN
Par 3-36 uses an IEC inlet rated at 10A, 240V as standard. The fixture will operate at voltages from
120VAC to 240VAC.
The power cord is a European color code type and should be connected as follows:
NOTE:
Only qualified personnel should attempt to change the electrical power connector.
Fuse – 2A, 250V Fuse must be replaced with the proper type and rating.
Data Input
The fixture uses standard DMX. The fixture uses 3-pin XLRs for DMX data input and thru.
The Data connections for a 3-pin XLR are as follows:
Pin 1 =
GND/Shield
Pin 2 =
Data (-)
Pin 3 =
Data (+)
Adapting a 5-pin XLR data feed to 3-pin XLR is as follows:
5-pin XLR
3-pin XLR
Pin 1
-
Pin 1
Pin 2
-
Pin 2
Pin 3
-
Pin 3
Pin 4
-
N/C
Pin 5
-
N/C
Page 3
208V
Brown
–
Phase 1
Blue
–
Phase 2
Green/Yellow –
Ground
120V
Brown
–
Hot
Blue
–
Neutral