Model T28798 (Mfd. Since 12/18)
-19-
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
Test Run
Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning correctly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The
Troubleshooting table in the
SERVICE section of this manual can help.
To test run machine:
1. Clear all setup tools away from machine.
2. Connect machine to power supply.
3. Remove disabling pin from paddle switch, as
shown in
Figure 15.
Figure 15. Removing disabling pin from paddle
switch.
Serious injury or death can result from
using this machine BEFORE understanding
its controls and related safety information.
DO NOT operate, or allow others to operate,
machine until the information is understood.
4. Turn machine ON, verify motor operation,
and then turn machine
OFF.
Machine should run smoothly and without
problems or unusual noises.
5. Insert disabling pin into paddle switch.
6. Attempt to start machine by pushing ON but-
ton with pin installed.
Machine should NOT start. If it does start,
the switch disabling feature is not functioning
properly and the switch must be replaced.
The Test Run consists of verifying the following:
1) The motor powers up and runs correctly, and
2) the safety disabling mechanism on the switch
works correctly.