-24-
Model G0821 (Mfd. Since 03/18)
3. Use a 90° square to adjust fence to 90° (see
Figure 26), then tighten fence tilt lock.
Note:
Fence should stop at 90º when it con-
tacts limit block shaft.
— If fence does not stop at 90° when it
contacts limit block shaft, 90° stop is not
adjusted correctly. Proceed to
Steps 6–9.
4. Bring fence to 90°, then loosen jam nut locat-
ed on rear of limit block shaft (see
Figure 27)
Note: Keep limit plate in limit block rear slot
while making adjustments (see
Figure 27).
Setting Fence Stops
The fence stops simplify the task of adjusting the
fence to 45° inward, 90°, and 45° outward (135°).
Tools Needed
Qty
45° Square ........................................................ 1
90° Square ........................................................ 1
Sliding Bevel ...................................................... 1
Open-End Wrench 10mm .................................. 1
Hex Wrench 6mm .............................................. 1
Figure 26. Checking the 90º stop.
Machinist's
Square
Figure 25. Fence carriage overview.
Fence
Tilt Lock
Lever
Fence Carriage
Lock Lever
Setting 90° Fence Stop
1. DISCONNECT MACHINE FROM POWER!
2. Loosen fence tilt lock (see Figure 25), and
press limit plate tab forward into limit block
rear slot.
Figure 27. Fence stop parts identification.
Limit Block
Shaft
Limit Plate
Tab
Inward Stop
Jam Nut
Limit Block
Rear Slot
5. Turn limit block shaft by hand until it contacts
fence.
6. Re-tighten jam nut. The 90° stop is now set
precisely.
Figure 28. Checking 45º fence stop.
Machinist's
Square
Setting 45° Fence Stop
1. DISCONNECT MACHINE FROM POWER!
2. Use a 45° square to adjust fence to 45° posi-
tion, as shown in
Figure 28.
Содержание G0821