Model G0757 (Mfg. Since 6/13)
-5-
Basic Controls
Refer to
Figures 1–3 and the following descrip-
tions to develop an understanding of the basic
controls used to operate the milling machine. This
knowledge will be necessary to safely complete
the
Test Run later in this manual.
Additional details for certain controls are also
located in the
Operations section.
Master Power Switch
Figure 1. Location of master power switch.
Master
Power Switch
Master Power Switch: Enables power to flow to
the machine when the “
l” is visible at the top of
the switch.
Master Control Panel
A. Power Lamp Button: When pressed, illu-
minates and enables power to both control
panels. Both Emergency STOP buttons must
be reset first.
B. Forward Button (Vertical Spindle): Starts
vertical spindle forward rotation (clockwise
looking down on the headstock).
C. Reverse Button (Vertical Spindle ): Starts
vertical spindle reverse rotation (counter-
clockwise looking down on the headstock).
D. STOP Button (Vertical Spindle ): Stops
vertical spindle rotation.
E. Emergency STOP Button: Disables power
to both control panels and stops all machine
functions. To reset, twist the button clockwise
until it pops out.
F. STOP Button (Horizontal Spindle ): Stops
horizontal spindle rotation.
G. Reverse Button (Horizontal Spindle ):
Starts horizontal spindle reverse rotation
(clockwise as viewed from the front of the
machine).
H. Forward Button (Horizontal Spindle ):
Starts horizontal spindle forward rotation
(counterclockwise as viewed from the front of
the machine).
I. Coolant Pump Switch: Starts/stops the
coolant pump and the flow of coolant.
Spindle rotation direction can ONLY be
changed when the spindle is completely
stopped.
Figure 2. Master control panel.
A
B
C
D
E
F
G
H
I
Содержание G0757