Model G0751 (Mfg. Since 1/13)
-37-
Checking/Adding Coolant
Tool Needed
Qty
hex Wrench 5mm .............................................. 1
To check/add coolant:
1. disConneCt MiLL FroM poWer!
2. remove coolant pump from base (see
Figure 46).
3. Use a clean metal tool as a dip stick to mea-
sure level of coolant in the reservoir. if level
is lower than 2", add coolant.
Note: Clean away debris and grime from
pump bottom screen before replacing it.
4. re-install coolant pump before resuming
operations.
Changing Coolant
Tools Needed
Qty
hex Wrench 5mm .............................................. 1
Catch pan .......................................................... 1
empty Bucket 5 gal........................................... 1
new Coolant ........................... approx. 2 gallons
To change the coolant:
1. put on personal protective equipment.
2. place catch pan on table, position the coolant
nozzle into pan, then use coolant pump to
drain reservoir.
Note: When catch pan is near full, empty it
into 5 gallon bucket, then repeat process.
3. disConneCt MaChine FroM poWer!
4. remove coolant pump and move it away.
5. thoroughly clean bottom of reservoir and
pump bottom screen. Make sure interior is
completely dry before adding new coolant.
Note: Use a cleaning solution that is compat-
ible with type of coolant. For instance, if you
are using a water-based coolant, then use a
water-based cleaning solvent.
6. When reservoir and pump are clean and dry,
re-fill the reservoir, and replace pump.
Tip: Place a couple of magnets inside res-
ervoir under return hose to collect metal par-
ticles to keep them out of coolant pump.
Figure 46. Coolant pump removed from base.
Coolant
pump
Содержание G0751