Model G0734/G0735 (Mfd. Since 12/15)
-27-
Table Tilt Calibration
4. Place the machinist's square behind the
blade, as shown in
Figure 34.
The table lock knob and tilt scale are used to tilt
the table for horizontal angle cuts.
Note: The table tilt scale is only an approximate
scale and should not be used when precise angle
measurements are required for the operation.
Tools Needed
Qty
Phillips Screwdriver #2 ...................................... 1
Wrench 10mm ................................................... 1
Machinist's Square 2" ........................................ 1
To calibrate the table tilt:
1. DISCONNECT MACHINE FROM POWER!
2. Raise the hold-down shoe at the maximum
height and lock it in place.
3. Loosen the table tilt lock knob (Figure 33).
5. Adjust the table to be square with the blade,
then tighten the lock knob.
6. Loosen the pointer screw, adjust the tip to the
0° mark on the scale, then tighten the screw
to secure the setting.
Figure 34. Squaring table to blade.
Blade
Machinist's
Square
Figure 33. Table tilt lock knob.
Table Tilt Lock Knob
Pointer Screw
Pointer
Fuse Replacement
If the fuse blows, the light will turn
ON but the
motor will not start. You can verify if the fuse
has blown or not by holding it up to the light and
inspecting the element inside the glass (the ele-
ment looks like a thin wire). If the fuse is blown the
element will be broken in half.
To replace the fuse:
1. DISCONNECT MACHINE FROM POWER!
2. Remove the switch cover, slide the circuit
board partially out, remove the fuse (
Figure
35), and install a new one.
3. Re-install the circuit board and the cover.
Figure 35. Location of fuse on circuit board.
Fuse
Содержание G0734