G0603X 25" Extreme Series Planer
-21-
Test Run
Once assembly is complete, test run your machine
to make sure it runs properly.
If, during the test run, you cannot easily locate
the source of an unusual noise or vibration,
stop using the machine immediately, then review
Troubleshooting
on
Page 33
.
If you still cannot remedy a problem, contact our
Tech Support at (570) 546-9663 for assistance.
To test run the machine:
1.
Make sure you have read the safety instruc-
tions beginning on
Page 8
and check to
ensure that your machine is set up properly.
2.
Make sure all tools and objects used during
set up are cleared away from the machine.
3.
Make sure the headstock cover is closed
and secured and that all access panels are
securely attached.
4.
Put on safety glasses and respirator; secure
loose clothing and long hair.
5.
Press the green MAIN MOTOR button on the
power/table control to turn the cutterhead/
feed motor
ON
.
6.
The planer should run smoothly with little or
no vibration. Listen for any abnormal noises
and watch for any unusual actions.
—If you suspect any problems, immedi-
ately stop the planer by pressing the red
EMERGENCY STOP button on the power/
table control. Refer to
Troubleshooting
on
Page 33
and fix any problems before start-
ing the planer again.
—If you need any help with your planer call
our Tech Support at (570) 546-9663.
7.
Use the green TABLE UP and TABLE DOWN
buttons on the power/table control to raise
and lower the table, and repeat
Step 6
for
each direction.
Safety Feature Tests
After completing the
Test Run
to your satisfac-
tion, perform the following procedures to verify
that all of the safety features of this planer are
operational.
Perform safety feature tests carefully and
pay close attention to each of the steps. If
any of the following tests fail, shut the power
OFF
at the CIRCUIT BREAKER immediately
and call our Tech Support at (570) 546-9663.
DO NOT turn the power ON for any reason
unless instructed to do so by our Tech
Support. Failure to follow this warning and
procedure could result in serious personal
injury or death!
To test the Emergency Stop lockout feature:
1.
Start the planer by pressing the MAIN MOTOR
button on the power/table control.
2.
Now press the EMERGENCY STOP but-
ton and let the planer come to a complete
stop. Leave the EMERGENCY STOP
button
pushed in.
3.
Press the TABLE UP and TABLE DOWN but-
tons. There should be NO table movement or
action from the planer of any kind.
Содержание G0603X
Страница 2: ... ...
Страница 5: ...G0603X 25 Extreme Series Planer 3 Machine Data Sheet ...
Страница 6: ... 4 G0603X 25 Extreme Series Planer ...
Страница 10: ... 8 G0603X 25 Extreme Series Planer ...
Страница 11: ...G0603X 25 Extreme Series Planer 9 Safety Instructions for Machinery ...
Страница 50: ... 48 G0603X 25 Extreme Series Planer Page 47 Page 47 Page 47 Page 47 Page 50 Page 50 Page 49 Page 51 Page 51 ...
Страница 51: ...G0603X 25 Extreme Series Planer 49 Page 47 Page 51 Page 51 Page 50 Page 50 Page 50 Page 48 ...
Страница 52: ... 50 G0603X 25 Extreme Series Planer Page 49 Page 48 Page 49 ...
Страница 53: ...G0603X 25 Extreme Series Planer 51 Page 49 ...
Страница 54: ... 52 G0603X 25 Extreme Series Planer Base Parts Breakdown ...
Страница 57: ...G0603X 25 Extreme Series Planer 55 Column Parts Breakdown ...
Страница 59: ...G0603X 25 Extreme Series Planer 57 Electric Parts Breakdown ...
Страница 61: ...G0603X 25 Extreme Series Planer 59 Gearbox Parts Breakdown ...
Страница 63: ...G0603X 25 Extreme Series Planer 61 Headstock Parts Breakdown ...
Страница 65: ...G0603X 25 Extreme Series Planer 63 Table Parts Breakdown ...
Страница 68: ......
Страница 69: ... ...
Страница 70: ... ...
Страница 72: ... ...