-58-
G0555XH
(Mfd. Since 1/18)
READ ELECTRICAL SAFETY
ON PAGE 57!
Run Capacitor
50uF 250VAC
110 VAC
5-15 Plug
Hot
Hot
Ground
220
VAC
G
Work Lamp
(110V ONLY! 40W Max.)
Rewired for 220V
Start Capacitor
300MFD 250VAC
Ground
Motor (110V)
Run Capacitor
50uF 250VAC
Start Capacitor
300MFD 250VAC
Ground
Motor (220V)
Rewired for 220V
Ground
Hot
Neutral
6-15 Plug
(As Recommended)
220 VAC
(Machine Body)
Ground
B1
A1
A3
B3
18A 125V
10A 250V
ON/OFF Switch
110 VAC
5-15 Plug
1
2
3
4
1
2
3
4
110V Wiring Diagram (Prewired)
Содержание G0555XH
Страница 72: ......