Model G0495X (Mfd. Since 07/19)
-23-
Digital Readout
Figure 18. Digital readout.
ABS/INC: Toggles between absolute and incre-
mental modes. Absolute mode shows the total
depth of cut in relation to an absolute zero point.
Incremental mode shows how much the table
has moved up or down in relation to an arbitrarily
chosen zero point. To select incremental mode,
press the ABS/INC button until INC is displayed.
To return to absolute mode, press the ABS/INC
button again.
For example, to use absolute and incremental
modes:
1. Press ABS/INC button to display ABS.
2. Press HOLD TO CAL button. This sets an
absolute zero point.
3. To move infeed table down, press + and -
buttons until display reads 0.125".
4. Press ABS/INC button to toggle to incremental
mode, press HOLD TO CAL button to set
arbitrary zero point, then move infeed table
up -0.010".
5. Press ABS/INC button to toggle back to
absolute mode. The screen displays 0.115",
the total depth of cut relative to absolute zero
point set in
Step 2.
MM/IN: Toggles between inch and metric
measurements.
To use calibration modes:
1. Press ABS/INC button to enter absolute
mode.
2. Raise or lower infeed table to desired cutting
depth.
3. Press ABS/INC button to enter incremental
mode.
4. Press HOLD TO CAL button to reset digital
readout to 0.000.
ON/OFF and HOLD TO CAL: Push to turn digital
readout
ON and OFF. Push and hold 3–5 sec-
onds to enter calibration mode. Push to reset dis-
play to 0.000 in incremental mode. Follow
Step 2
in the previous example to reset display to 0.000
in absolute mode.
ABS/INC
MM/IN
ON/OFF
HOLD TO CAL