Trouble Shooting
Problem
Possible cause
Fault correction
Device does not start
Mains voltage not on
Check plug socket, cable, line
and plug, where appropriate,
have repaired through electrical
specialist
On/Off switch (
13) defec-
tive
Repair by Service Centre
Worn carbon brushes
Defective motor
Device runs with inter-
ruptions
Power cable is damaged
Check the cable and have it
changed by the Service Centre if
necessary
Internal loose electrical con-
nection
Repair by Service Centre
On/Off switch (
13) defec-
tive
Blades become hot
Blades are blunt
Have the blades (
1) sharp-
ened or replaced (Service Cen-
tre)
Blades are notched
Have the blades (
1) checked
or replaced (Service Centre)
Too much friction due to lack
of lubrication
Oil the blades (
1)