background image

English

21

1.1 Safety information

1.1.1 Protecting against electric shock

• Disconnect the unit from mains supply before servicing it or performing any other action.

• Always ground/earth the unit electrically.

• Before connecting the unit to power supplies, verify that operating voltage and frequency are compatible.

• Do not handle the unit with wet hands or in the presence of water.

• Check regularly that the power supply cable is not damaged or crushed.

• Apply to a qualified technician for any regular maintenance action not described in this manual.

1.1.2 Installation

• Fix the unit with screws, hooks or any other support able to bear the weight of the unit itself.

• The unit installation actions must be performed by a qualified staff.

1.1.3 Protection against burns and fire

• 

Suitable to be installed onto normally inflammable surfaces.

• The unit is not to be installed in places where the ambient temperature exceeds 50° (122°F).

1.1.4 Weather protection

The unit is classified as device with an IP66 weather protection rate.

1.2 Warranty conditions

• Each product manufactured by GRIVEN srl of Italy is assembled and built in accordance to current CE con-

formity rules and regulations.

• Every single product and component has been tested before the final assembling and all products must pass

the in-house quality control before they are shipped.

• GRIVEN srl of Italy guarantees the good quality and manufacture of the products and undertakes to repair or

supply again, according to his opinion and free of charge, within the shortest time possible, any part that shows

- during the guarantee period - defects of constructions, manufacture or material.

• The guarantee is valid for 12 (twelve) months starting from the delivery date of the products.

• GRIVEN srl of Italy does not respond for damages occurred to the units during transport and for irrational use and

inaccuracy in regular maintenance of the products.

• The guarantee excludes all consumables.

• The customer will take care of the return of the faulty parts to GRIVEN srl of Italy, at his own charge and risk.

• The parts which have been repaired or replaced are sent by GRIVEN srl of Italy ex-factory.

• For any dispute, the Court of Mantova (Italy) will be competent and in conformity with relevant jurisdiction the

Italian Law is enforced for any controversy.

1.3 Compliance

• Product in compliance with EN60598-1 EN60598-2-17.

• Product in compliance with 2002/95/CE (RoHS).

1.0 Introduction

Warning!

This unit is suitable for professional use only, not for domestic use.

Содержание Powershine MK2 D

Страница 1: ...POWERSHINE MK2 D Manuale di istruzioni Instructions manual...

Страница 2: ...ons with DMX MODE 12 channels 28 6 4 DMX functions dynamic white 29 6 4 1 DMX functions with DMX MODE 2 channels 29 6 4 2 DMX functions with DMX MODE 3 channels 29 6 4 3 DMX functions with DMX MODE 4...

Страница 3: ...ormity rules and regulations Every single product and component has been tested before the final assembling and all products must pass the in house quality control before they are shipped GRIVEN srl o...

Страница 4: ...o transport the unit 2 0 Size 696mm 27 41in 567mm 22 32in 334mm 13 16in 682mm 26 85in 12 5mm 0 5in 150mm 5 91in 300mm 11 81in 3 0 Packaging and transport Warning Griven S r l liability will cease upon...

Страница 5: ...an operate in any position Use the holes 12 5 1 2 or 6 5 1 4 in the bracket to fix the unit 4 2 Adjusting light beam direction 1 Untighten the lateral screw 3 2 Rotate the bodies of the unit towards d...

Страница 6: ...pplies features are compatible with the unit features The unit must never be installed if not grounded electrically It is suggested to use a magnetothermic switch along the power supply line as prescr...

Страница 7: ...y of the unit is programmed to turn off automatically after 10 seconds of non working To activate it just press any key In the presence of the DMX signal the red led will steadily be on while in the a...

Страница 8: ...ess ENTER to confirm 6 3 DMX functions RGBW 6 3 1 DMX functions with DMX MODE 4 channels 6 3 2 DMX functions with DMX MODE 5 channels 6 0 DMX function mode Warning In absence of DMX signal the led wil...

Страница 9: ...0 100 of the Blue color of the upper cluster 4 White 0 255 Proportional control 0 100 of the White color of the upper cluster 5 Red 0 255 Proportional control 0 100 of the Red color of the lower clus...

Страница 10: ...pper cluster 4 White 0 255 Proportional control 0 100 of the White color of the upper cluster 5 Dimmer 0 5 Luminous output intensity 0 of the upper cluster 6 250 Proportional control of the luminous o...

Страница 11: ...te 100 2 Dimmer Strobe 0 15 Luminous output intensity 100 16 150 Proportional control of the luminous output intensity 100 0 151 160 Luminous output intensity 0 161 255 Proportional control of the str...

Страница 12: ...luster 151 160 Luminous output intensity 0 upper cluster 161 255 Proportional control of the strobe effect 0 100 255 max upper cluster 3 Dynamic white 0 3 Warm white 100 Cold white 0 lower cluster 4 1...

Страница 13: ...intensity 100 0 lower cluster 151 160 Luminous output intensity 0 lower cluster 161 255 Proportional control of the strobe effect 0 100 255 max lower cluster Warning In absence of DMX signal the led w...

Страница 14: ...Press ENTER to confirm It is possible to adjust the length of time of the scenes of the programmes Through the UP and DOWN keys select TI and press ENTER to confirm Through the UP and DOWN keys selec...

Страница 15: ...eep reading COL To exit from the FIXED COLOURS mode press the MENU button select ACT and press ENTER to confirm Select OFF to deactivate the FIXED COLOURS mode Press ENTER to confirm 8 2 Dynamic white...

Страница 16: ...re of led drivers which should never be higher than 70 C will appear A higher value indicates a malfunction of the fixture With this operation the working temperature of Body can be checked Press the...

Страница 17: ...ating temperature value is displayed An internal temperature sensor prevents the unit from overheating The temperature sensor will limit the current to leds protecting their integrity if the ambient t...

Страница 18: ...y or of the rear boxes the screws of the glass holder must be tightened by a 4 Nm tightening torque while the screws of the rear boxes by a 2 5Nm tightening torque All components of the unit are avail...

Страница 19: ...wires Rectify inefficient connec tions Repair or replace damaged wires Unfinished data connection Insert a terminal plug in the output jack of the last unit of the connection Incorrect address assign...

Страница 20: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 2...

Отзывы: