can operate without DMX signal (in AUTOMATIC mode) and can be set so that a single MAS-

TER unit will command a series of SLAVE units. This function is particularly useful when more units are desired to ex-

ecute the same programme in synchrony.

The following picture shows an example of a Master-Slave layout.

7.1 AUTOMATIC configuration

RGBW - The AUTOMATIC mode ONLY works when set to operate with 5 DMX channels.

DW - The AUTOMATIC mode ONLY works when set to operate with 3 DMX channels.

Follow this description to modify the DMX channels setting: press the “MENU” button, select “CHN” and press

“ENTER” button to activate the function. Then select 5C through the “UP” and “DOWN” keys. Press “ENTER” to

confirm.

To activate the AUTOMATIC mode, press the “MENU” button up to visualize “ADR”. Through the “UP” and “DOWN”

keys select “AUT”. Press “ENTER” to confirm.

Through the “UP” and “DOWN” keys select “ACT”. Through the “UP” and “DOWN” keys select “ON” or “OFF” to

activate or deactivate the AUTOMATIC mode. Press “ENTER” to confirm.

It is possible to adjust the length of time of the scenes of the programmes.

Through the “UP” and “DOWN” keys select “TI” and press “ENTER” to confirm. Through the “UP” and “DOWN” keys

select the length of time desired (5-10-20-40 seconds) and press “ENTER” to confirm.

Now, through the “UP” and “DOWN” keys, it is possible to scroll the 8 preset programmes (P1-P8). Once positioned

onto the desired programme, press “ENTER” to confirm. By the keys “UP”and “DOWN” select “ON” or “OFF”. It is

possible to activate or disactivate the programme. Press ENTER to confirm. 

Now the unit is in AUTOMATIC mode and the diplay will keep reading “AUT”.

To exit from the AUTOMATIC mode, press the “MENU” button, select “ACT” and press “ENTER” to confirm. 

Select “OFF” to deactivate the AUTOMATIC mode. Press ENTER to confirm. 

7.0 Master-Slave and Automatic function (only RGBW and DW)

MASTER

SLAVE 1

SLAVE N

IN

OUT

IN

OUT

SLAVE 2

IN

OUT

OUT

Terminal 

(R=120 

ƺ

  not  

included!)

Warning! 

It is possible to select more programmes which will be executed in sequence.

If MASTER-SLAVE mode is being used, the fixture cannot be controlled by a DMX control device and no other

DMX control device must be present along the line!! 

32

English

Содержание Powershine MK2 D

Страница 1: ...POWERSHINE MK2 D Manuale di istruzioni Instructions manual...

Страница 2: ...ons with DMX MODE 12 channels 28 6 4 DMX functions dynamic white 29 6 4 1 DMX functions with DMX MODE 2 channels 29 6 4 2 DMX functions with DMX MODE 3 channels 29 6 4 3 DMX functions with DMX MODE 4...

Страница 3: ...ormity rules and regulations Every single product and component has been tested before the final assembling and all products must pass the in house quality control before they are shipped GRIVEN srl o...

Страница 4: ...o transport the unit 2 0 Size 696mm 27 41in 567mm 22 32in 334mm 13 16in 682mm 26 85in 12 5mm 0 5in 150mm 5 91in 300mm 11 81in 3 0 Packaging and transport Warning Griven S r l liability will cease upon...

Страница 5: ...an operate in any position Use the holes 12 5 1 2 or 6 5 1 4 in the bracket to fix the unit 4 2 Adjusting light beam direction 1 Untighten the lateral screw 3 2 Rotate the bodies of the unit towards d...

Страница 6: ...pplies features are compatible with the unit features The unit must never be installed if not grounded electrically It is suggested to use a magnetothermic switch along the power supply line as prescr...

Страница 7: ...y of the unit is programmed to turn off automatically after 10 seconds of non working To activate it just press any key In the presence of the DMX signal the red led will steadily be on while in the a...

Страница 8: ...ess ENTER to confirm 6 3 DMX functions RGBW 6 3 1 DMX functions with DMX MODE 4 channels 6 3 2 DMX functions with DMX MODE 5 channels 6 0 DMX function mode Warning In absence of DMX signal the led wil...

Страница 9: ...0 100 of the Blue color of the upper cluster 4 White 0 255 Proportional control 0 100 of the White color of the upper cluster 5 Red 0 255 Proportional control 0 100 of the Red color of the lower clus...

Страница 10: ...pper cluster 4 White 0 255 Proportional control 0 100 of the White color of the upper cluster 5 Dimmer 0 5 Luminous output intensity 0 of the upper cluster 6 250 Proportional control of the luminous o...

Страница 11: ...te 100 2 Dimmer Strobe 0 15 Luminous output intensity 100 16 150 Proportional control of the luminous output intensity 100 0 151 160 Luminous output intensity 0 161 255 Proportional control of the str...

Страница 12: ...luster 151 160 Luminous output intensity 0 upper cluster 161 255 Proportional control of the strobe effect 0 100 255 max upper cluster 3 Dynamic white 0 3 Warm white 100 Cold white 0 lower cluster 4 1...

Страница 13: ...intensity 100 0 lower cluster 151 160 Luminous output intensity 0 lower cluster 161 255 Proportional control of the strobe effect 0 100 255 max lower cluster Warning In absence of DMX signal the led w...

Страница 14: ...Press ENTER to confirm It is possible to adjust the length of time of the scenes of the programmes Through the UP and DOWN keys select TI and press ENTER to confirm Through the UP and DOWN keys selec...

Страница 15: ...eep reading COL To exit from the FIXED COLOURS mode press the MENU button select ACT and press ENTER to confirm Select OFF to deactivate the FIXED COLOURS mode Press ENTER to confirm 8 2 Dynamic white...

Страница 16: ...re of led drivers which should never be higher than 70 C will appear A higher value indicates a malfunction of the fixture With this operation the working temperature of Body can be checked Press the...

Страница 17: ...ating temperature value is displayed An internal temperature sensor prevents the unit from overheating The temperature sensor will limit the current to leds protecting their integrity if the ambient t...

Страница 18: ...y or of the rear boxes the screws of the glass holder must be tightened by a 4 Nm tightening torque while the screws of the rear boxes by a 2 5Nm tightening torque All components of the unit are avail...

Страница 19: ...wires Rectify inefficient connec tions Repair or replace damaged wires Unfinished data connection Insert a terminal plug in the output jack of the last unit of the connection Incorrect address assign...

Страница 20: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 2...

Отзывы: