5.1 Setting operating mode
By using an infrared remote control (code AL1321) featuring an RC5 control, it is possible to select one of the fol-
lowing operating mode.
• using DMX512 signal control mode
Each fixture is controlled from DMX512 signal control.
• MASTER-SLAVE or AUTOMATIC mode
The projector operates independently, without DMX512 signal control. (see chapter 8)
Every button push is confirmed by a very short flash coming from the projector.
5.2 Setting DMX Address
By using the remote control (AL1321) it is possible to select the DMX address and mode:
Warning!
Before performing any setting operation it is necessary to log in as reported in the chart below.
Function
Buttons
Description
LOGIN
It is the first procedure to be performed. After pushing the buttons 1, 2, 3 it is pos-
sible to access the functions settings. The function is confirmed by 1 white flash
coming from the projector.
LOGOUT
/
The logout is automatic after 5 minutes of missing reception of the signal coming
from the remote control. Once th projector logs out it is not possible to perform
any other operation before a new login.
5.0 Use of the unit
Function
Buttons
Description
Change of
DMX mode
RGBW
+ 4 / 5 / 6
Select 3, 4 or 5 DMX channels. If the setting is correct then the projector will con-
firm the procedure by performing 2 white flashes.
Change of
DMX mode
DW
+ 2 / 3
Select 2 or 3 DMX channels. If the setting is correct then the projector will confirm
the procedure by performing 2 white flashes.
Change
of DMX
address
+ 0....9
79ʗ
The new entered address must feature 3 digits (e.g. 0 6 7). If the address is correct
then the projector will confirm the procedure by performing 3 white flashes
20
English