5.4 DMX functions Dynamic white

5.4.1 DMX functions with DMX MODE = 2 channels

5.4.2 DMX functions with DMX MODE = 3 channels

5.5 DMX functions monochrome

Warning!

In absence of DMX signal the led will remain ON.

Channel Function

Value

Description

1

Dynamic

white

0-3

Warm white 100% - Cold white 0%

4-122

Warm white 100% - Cold white from 0% to 100%

123-132

Warm white 100% - Cold white 100%

133-251

Warm white 100% to 0% - Cold white 00%

252-255

Warm white 0% - Cold white 100%%

2

Dimmer

Strobe

0-15

Luminous output intensity 100%

16-150

Proportional control of the luminous output intensity 100-0%

151-160

Luminous output intensity 0%

161-255

Proportional control of the strobe effect 0-100% (255=max)

Channel Function

Value

Description

1

Warm

white

0-255

Proportional control 0¬-100% of the warm white

2

Cold

white

0-255

Proportional control 0¬-100% of the cold white

3

Dimmer

Strobo

0-15

Luminous output intensity 100%

16-150

Proportional control of the luminous output intensity 100-0%

151-160

Luminous output intensity 0%

161-255

Proportional control of the strobe effect 0-100% (255=max)

Attention! 

In absence of DMX signal the led will remain ON.

Channel Function

Value

Description

1

Dimmer

Strobe

0-15

Luminous output intensity 100%

16-150

Proportional control of the luminous output intensity 100-0%

151-160

Luminous output intensity 0%

161-255

Proportional control of the strobe effect 0-100% (255=max)

22

English

Содержание Jade 16 AL4050

Страница 1: ...Jade 16 AL4050 Manuale di istruzioni Instructions manual...

Страница 2: ...ions with DMX MODE 5 channels 21 5 3 3 DMX functions with DMX MODE 6 channels 21 5 4 DMX functions Dynamic white 22 5 4 1 DMX functions with DMX MODE 2 channels 22 5 4 2 DMX functions with DMX MODE 3...

Страница 3: ...action not described in this manual 1 1 2 Installation Fix the unit with screws hooks or any other support able to bear the weight of the unit itself The unit installation actions must be performed by...

Страница 4: ...e unit 2 0 Size 116mm 4 57 114mm 4 47 194mm 7 62 8 m m 0 3 1 9 m m 0 3 3 19mm 0 76 114mm 4 47 160mm 6 30 3 0 Packaging and transport Warning Griven S r l liability will cease upon consignment of goods...

Страница 5: ...bile structure truss To fix the unit onto a supporting structure or truss it is suggested to use hooks 4 type Aliscaff The hooks are to be fitted to the unit through the holes in the bracket as shown...

Страница 6: ...electrically It is suggested to use a magnetothermic switch along the power supply line as prescribed by in force rules The unit must not be powered up through a dimmer power device Wiring and connec...

Страница 7: ...med After pushing the buttons 1 2 3 it is pos sible to access the functions settings The function is confirmed by 1 white flash coming from the projector LOGOUT The logout is automatic after 5 minutes...

Страница 8: ...oportional control 0 100 of the Blue color 4 White 0 255 Proportional control 0 100 of the White color 5 Dimmer Strobe 0 15 Luminous output intensity 100 16 150 Proportional control of the luminous ou...

Страница 9: ...output intensity 0 161 255 Proportional control of the strobe effect 0 100 255 max Channel Function Value Description 1 Warm white 0 255 Proportional control 0 100 of the warm white 2 Cold white 0 25...

Страница 10: ...uration Dynamic white To set up the unit as SLAVE set the 3 channels DMX mode with address 001 MASTER SLAVE 1 SLAVE N IN OUT IN OUT SLAVE 2 IN OUT Terminal resistor R 120 not included 6 0 Master Slave...

Страница 11: ...mode is activated or deactivated by the TV key Colour selection 1 2 3 4 Select the colour whose intensity is intended to be adjusted by the keys from 1 to 4 1 red 2 green 3 blue 4 white Colour intensi...

Страница 12: ...lly on the environment where the unit will operate deposits of dust smokes or other wastes will reduce the light output performances Clean regularly the glass of the unit Be careful when cleaning the...

Страница 13: ...on of the firmware in use on the projector is displayed Temperature The LEDs operating temperature value is displayed The European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEE...

Страница 14: ...espond properly to the DMX control Incorrect DMX cable connection Check connections and wires Rectify inefficient connec tions Repair or replace damaged wires Unfinished data connection Insert a termi...

Страница 15: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 1...

Отзывы: