6.5 Replacing the optic groups
The unit can be fitted with different optic groups according to application requirements.
The standard optics is 12°, but 22° and 34° optics are available on request.
Necessary actions to replace the optic groups are shown in the following pictures:
1.
Untighten the 6 screws
“F”
and open the units.
2.
Untighten the screws
“N”
and replace the lens group
.
3.
Close the unit again by tighten the screw
“F”
previously removed.
6.6 Powering up the unit
Once performed all actions described in the previous paragraphs, you can proceed and power up the unit.
The green led next to the dip switch panel will turn on.
In the presence of DMX signal, the red led will remain constantly on, in the absence of DMX signal the yellow led
will remain off, while in Master mode the red led will flash.
Warning!
Operate the units with the front panel open for 30-40 minutes
before closing them for permanent use. This precaution will
avoid the forming of condensation on the front glass.
3-4 cm
Warning!
Make sure that the front panel gasket is properly positioned in order to avoid water infiltrations into the unit.
N
F
F