6.1.2 Installation onto a mobile structure (truss)
To fix the unit onto a supporting structure or truss, it is suggested
to use hooks
“D”
type “Aliscaff”. The hooks are to be fitted to the
unit through the holes in the bracket, as shown in the picture.
6.2 Adjusting light beam direction
1.
Untighten the lateral screw
“E”
, rotate the body of the unit to-
wards desired direction and tighten the knobs.
2.
Rotate the body of the unit towards desired direction and
tighten the screw
“E”
.
6.3 Connection to mains power
The unit can operate with voltage from 200 to 250Vac and with frequency of 50 and 60Hz, according to the pre-
set by Griven.
Refer to the label onto the panel of the unit to check the preset.
¢
AL1800
¢
AL1802
¢
AL1804
¢
100/115 V
¢
200/208/220 V
¢
230/240/250 V
¢
50 Hz
¢
60 Hz
¢
AL1808
¢
AL1810
¢
AL1812
Danube Full Colour
E
Warning!
Check that the fixing hook is not damaged and is able to bear at least 10 times the weight of the unit.
Check that the structure can bear at least 10 times the weight of the unit,
the hooks, the additional equipments, etc.
D
22
English