5.0 WARRANTY CONDITIONS

• Each product manufactured by GRIVEN srl of Italy is assembled and built in accor-

dance to current CE conformity rules and regulations.

• Every single product and component has been tested before the final assembling

and all products must pass the in-house quality control before they are shipped.

• GRIVEN srl of Italy guarantees the good quality and manufacture of the products

and undertakes to repair or supply again, according to his opinion and free of

charge, within the shortest time possible, any part that shows - during the guar-

antee period - defects of constructions, manufacture or material.

• The guarantee is valid for 12 (twelve) months starting from the delivery date of the

products.

• GRIVEN srl of Italy does not respond for damages occurred to the units during

transport and for irrational use and inaccuracy in regular maintenance of the

products.

• The guarantee excludes all consumables.

• The customer will take care of the return of the faulty parts to GRIVEN srl of Italy,

at his own charge and risk.

• The parts which have been repaired or replaced are sent by GRIVEN srl of Italy ex-

factory.

• For any dispute, the Court of Mantova (Italy) will be competent and in conformi-

ty with relevant jurisdiction the Italian Law is enforced for any controversy.

6.0 COMPLIANCE

• Product in compliance with EN60598-1 EN60598-2-17.

• Product in compliance with 2002/95/CE (RoHS).

7.0 TECHNICAL INFORMATION

LED DOP CONTROLLER

Operating voltage

230/240

Vac

Operating frequency

50/60

Hz

Protection rating

IP65

Operating temperature

-20 / 40

°C

18

Содержание AL1419

Страница 1: ...LED DOP CONTROLLER AL1419 Manuale di istruzioni Instructions manual...

Страница 2: ...unzionamento 5 3 3 Funzionamento in modalit AUTOMATICO 6 3 4 Funzionamento in modalit COLORI 7 3 5 Funzionamento in modalit PROGRAMMA 7 3 6 Funzionamento in modalit OROLOGIO 8 3 7 Funzionamento in mod...

Страница 3: ...LER 13 3 1 Control panel 13 3 2 Function mode 13 3 3 AUTOMATIC mode 14 3 4 COLOR mode 15 3 5 PROGRAM mode 15 3 6 TIMER mode 16 3 7 OFF mode 17 3 8 DIMMER mode 17 3 9 Set operating language and date ti...

Страница 4: ...trico La figura seguente indica il collegamento alle morsettiere sul retro del CONTROLLER Collegare all ingresso del trasformatore il filtro di rete come indicato in figura Pin 1 n c Pin 2 n c Pin 3 u...

Страница 5: ...itte qui di seguito Automatico Premete i tasti UP o DOWN per portare il cursore su FUNCT Premete ENTER per acce dere alle funzioni e selezionate uno degli 8 programmi automatici da AUTOM 1 a AUTOM 8 P...

Страница 6: ...tori CYM con 3 canali DMX Trident Vesuvio Colosseo ecc Modo 003 Proiettori CYM con 5 o 6 canali DMX Graphite Stelvio Everest Kolorado ecc 3 3 Funzionamento in modalit AUTOMATICO E possibile selezionar...

Страница 7: ...PROGRAMMI e confermate con ENTER Selezionate uno dei 4 programmi personalizzabili e confer mate con ENTER Impostate il numero di scene Num Scene che compongo no il programma Max 16 e confermate con EN...

Страница 8: ...ando i valori visualizzati sul display 3 6 Funzionamento in modalit OROLOGIO Tenete premuto il tasto ENTER per 5 secondi per entrare nel MENU Tramite i tasti UP e DOWN selezionare OROLOGIO e confermat...

Страница 9: ...econdi per entrare nel MENU Tramite i tasti UP e DOWN selezionare LINGUA o DATA ORA e confermate con ENTER Impostate i valori desiderati e confermate premendo ENTER Premere ESC un numero di volte suff...

Страница 10: ...odotto GRIVEN Srl non risponde dei danni riportati dal prodotto durante il trasporto oppu re derivanti da un utilizzo improprio o da un inappropriata manutenzione dello stesso Sono escluse dalla prese...

Страница 11: ...NOTE 11...

Страница 12: ...erminal boards at the rear of LED D O P CONTROLLER Please connect the power supply filter to the transformer input as shown in the picture Pin 1 n c Pin 2 n c Pin 3 DMX output data Pin 4 DMX output da...

Страница 13: ...ccessible by using the functions described here below Automatic Press the keys UP or DOWN to lead the cursor to FUNCT Press ENTER to access the functions and select one of the 8 automatic programmes f...

Страница 14: ...Mode 002 CYM units with 3 DMX channels Trident CYM 150 Vesuvio OS CYM 250 etc Mode 003 CYM units with 5 or 6 DMX channels Graphite Stelvio CYM 300 Everest CYM 900 Kolorado etc 3 3 AUTOMATIC mode It i...

Страница 15: ...R key Select one of the 4 adjustable programs and confirm by the ENTER key Set the number of scenes Scenes No which make up the program maximum 16 confirm by the ENTER key PROG 2 Scenes No 6 Scene Set...

Страница 16: ...IMER mode Keep the Enter key pressed for 5 seconds to enter the MENU By the UP and DOWN keys select Timer and confirm by the ENTER key Select the first zone to be set and press Enter Set the starting...

Страница 17: ...enter the MENU By the UP and DOWN keys select LANGUAGE or DATE TIME and confirm by the ENTER key Set the value and confirm by the ENTER key After setting press ESC for the number of times necessary to...

Страница 18: ...from the delivery date of the products GRIVEN srl of Italy does not respond for damages occurred to the units during transport and for irrational use and inaccuracy in regular maintenance of the produ...

Страница 19: ...one delle apparecchiature i detentori potranno rivolgersi al servizio pubblico preposto o ai rivenditori Important information for the correct recycle treatment procedures of this equipment The Europe...

Страница 20: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 3...

Отзывы: