MAINTENANCE
DANGER
Never perform maintenance on the compressor when it is running. Always place On/Off switch in “OFF”
position, disconnect air hoses, drain air tanks, and allow unit to cool first. Performing service
procedures on a compressor with pressurized tanks, or with On-Off switch in the “ON” position, can
result in serious injury.
COMPRESSOR MAINTENANCE SCHEDULE
Interval Maintenance
Required
Check compressor pump oil level, and fill as needed.
Drain moisture from tanks daily. Open drain slowly and let air pressure bleed down gradually before
opening drain valve completely.
Perform a visual inspection of compressor. Make sure belt guard is in place, and all components are
in good condition.
Daily
Check for unusual noise or vibration during operation, and have problem corrected. Contact your
Grip-Rite dealer for service.
Check intake air filters and clean with soapy water if necessary. Rinse and allow to dry before use.
Replace filter if worn or damaged.
Check Pressure Relief Valve for proper operation. With tank pressurized, pull on Pressure Relief
Valve ring. Air must exhaust when ring is pulled. Release ring - air must stop exhausting when ring
is released.
Check V-belt for damage or wear, and replace if necessary.
Clean dust and debris from cylinder heads, fan blades, intercooler, and air tanks.
Weekly
Check for leaks, cracks, or corrosion on tank, fittings, and tubing. Discontinue use of equipment if
leaks or other major problems are found, and repair unit before placing back into service.
Change compressor oil and air filter.
Clean/blow off compressor pump fins and motor.
Check for air leaks at connections, and tighten fittings if necessary.
Check tank for cracks, corrosion, leaks, or other damage. Never use a compressor with a damaged
tank.
3 Months/
300 Hours
Check warning labels for legibility, and replace if necessary. Contact your Grip-Rite dealer for
replacement labels.
Belt Replacement/Adjustment
1. Shut off compressor and open drain cock to relieve pressure.
2. Remove belt guard
3. Belt Replacement: Loosen motor bolts and slide motor toward compressor head to allow belt to be
removed. Install new belt.
4. Belt Adjustment: Loosen motor bolts and move motor to provide recommended tension as shown on
page 8.
5. Make sure pulleys are aligned properly by placing a straight edge against pulleys.
6. Tighten motor bolts securely, and recheck alignment.
7. Replace belt guard
8. Close drain cock and restart compressor.
9. Check belt tension after first 20 hours of operation, then check monthly.
10