13
USE AND CARE INSTRUCTIONS
Check all connections for LP Gas Leaks
Never
test for leaks with a flame. Prior to first use,
at the beginning of each season, or every time
your LP Gas tank is changed, you must check for
gas leaks. Follow these three steps:
Make a soap solution by mixing one part liquid
detergent and one part water.
Turn the grill Control Knobs to the full OFF
position, then turn the gas ON at source.
Apply the soap solution to all gas connections
indicated by the arrows. See diagram. If
bubbles appear in the soap solution the
connections are not properly sealed. Check
each fitting and tighten or repair as necessary.
WARNING
!
!
If you have a gas leak that cannot be repaired
by tightening, turn off the gas at the source,
disconnect fuel line from your grill and call
1-800-667-7313
or your gas supplier for repair
assistance.
CAUTION: Always open both left and right Lid
as shown before lighting your grill.
Disconnecting A Liquid Propane Gas (LPG)
Tank From Your Grill
Never disconnect the gas regulator or any gas
fitting while your grill is lit. A lit grill can ignite
leaking gas and cause a fire or explosion which
could result in property damage, personal injury
or death.
Make sure the Burner Valves and LP Gas tank valve
are off. (Turn clockwise to close.)
Detach the hose and regulator assembly from the
LP Gas tank valve by turning the Quick Coupling
Nut counterclockwise.
Lock Casters while
your grill is in use
LPG Regulator with Hose
LP Gas Tank