MAINTENANCE
Frequently examine the installation for signs of
wear or damage. Do not use if repair or
adjustment is necessary. Power must be turned
off before servicing, cleaning or adjusting the
opener.
Certain mechanical aspects of the installation as
applicable must be checked, see below:
MONTHLY
• Examine the installation for signs of wear or
damage. Do not use if repair or adjustment is
necessary *
• Check chain alignment, tension and condition.
Adjust / replace if required *
• Check PE / IR beam/s and bump edge
functionality where applicable
QUARTERLY
• Check tightness of fixing bolts and (sprocket)
grub screws. Adjust if required *
• Check correct electrical operation
• Check manual operation as per the respective
“Installation and users Manual”
• Lubricate the drive chain *
* SERVICE MUST BE CARRIED OUT BY A
QUALIFIED TECHNICIAN
CHECK DOOR CYCLE COUNT
Door cycle count can only be checked if the
GLMe2L Logic Controller is installed. Limits must
be set.
• Drive door to closed limit
• Press and hold CLOSE for 10 seconds
• After 10 seconds and while still holding
CLOSE, press and release the SET button
• Status LED will light up indicating number of
cycles performed
To read number of cycles, follow the ‘Reading
Status Flashes’ routine described below.
Reading Status Flashes (GLMe2 controllers only)
STATUS indicator will start flashing to signify the
value of the least significant digit of the overall
number. A solidly lit indicator stands for zero.
Press set to view the next digit.
Continue previous step until the STATUS indicator
flashes quickly for 1 second then goes out. This
signifies that the entire number has been
displayed.
To reset error (GLMe2 controllers only)
(This process indicates there has been a severe
problem. Persistent resetting will void warranty
and may damage the door and/or opener). This
procedure will only work when the status light is
flashing 4, 5, 9, 10, 14 or 15 times.
Hold the STOP button for 10 seconds
While still holding the STOP button, press and
release the SET button
The STATUS indicator should flash quickly for 1
second. Any errors that were flashing should have
stopped.
Power MUST be turned off before servicing or adjusting the opener.
Disconnect the supply when cleaning!
WARNING